Manual of 11/06/2019 Rev. 1.8 “User Manual for 3000SP storage inverter”
Below are the instantaneous information and values that can be seen by pressing the “Down” key
from the main interface.
Grid (V)
Indicates the voltage of the grid in Volts
Grid (A)
Indicates the current exchanged with the grid in Ampere (the symbol – in front
of the figure indicates a transfer of power to the grid)
Frequency
Indicates the frequency of the grid expressed in Hertz
Battery (V)
Indicates the voltage of the battery pack expressed in Volts
Charge current
Indicates the current at which the battery pack is currently being charged
Discharge
current
Indicates the current at which the battery pack is currently being discharged
Charge level
Indicates the charge percentage of the battery pack
Battery cycles
Indicates the number of complete charging and discharging cycles performed
by the battery pack
Battery Temp.
Indicates the temperature measured on the cells of the battery pack
2)
Set %Charge Mode
Select “2. Set %Charge Mode” and press “OK” to enter the menu for setting this %Charge. In this mode,
the user can select one or more time intervals (both hourly and daily) during which the battery will be
forced to charge, also drawing power from the grid if the power supplied by the photovoltaic system is
not sufficient. The maximum charge level (SOC) and the power with which the battery will be
recharged can also be set.
This mode allows optimising the withdrawal of energy from the grid in time intervals when the prices
are different and more convenient. Below is an example of the screen.
Set %Charge Mode
Rules. 0: Enable
From To SOC Charge
21h00m - 06h00m 090% 1000W
Effective date
Dec. 22 - Mar. 21
Week days
Mon. Tue. Wed. Thu. Fri. Sat. Sun.