background image

Indicates insufficient distance between the Signal Antennas and Base Unit Antenna. The amplifier is operating at significantly

The amplifier is disabled.

For questions or assistance, contact zBoost customer service at 1-800-871-1612 or email [email protected]

CUSTOMER SERVICE 

FCC Information

FCC ID: SO4YX545-PCS-CEL

Warning: Changes or modifications to this device not expressly approved by zBoost could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference 

to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 

try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna

• Increase the separation between the equipment and receiver

• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected

• Consult the dealer or an experienced radio/TV technician for help

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located 

or operating in conjunction with any other antenna or transmitter. In accordance with FCC requirements of human exposure to radio frequency 

fields, the radiating element (antenna) shall be installed such that a minimum separation distance of 20cm (8in) is maintained from all persons.

Industry Canada Regulations

Canada IC: 5544A-YX545PCSCEL

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, 

including interference that may cause undesired operation.

The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.

RF Exposure:

The manufacturer’s rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, 

the rating would have to be reduced by 3.5 dB, especially where the output is re-radiated and can cause interference to adjacent band users. 

This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.

Please note: This unit has been approved for use in Canada under RSS 131, however, consent for the use of this device to improve cellular or 

PCS coverage, must be obtained through your cellular or PCS provider, prior to placing the unit in operation. Please refer to the Industry Canada 

document CPC 2-1-05, Section 6.1 available or viewable at: http://www.ic.gc.ca/epic/site/smt-gst.nsf/en/sf08942e.html

Cet appareillage numérique de la classe [B] répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. 

L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter 

n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

Le fabricant nominale de la puissance de sortie de ce matériel est simple transporteur. Pour les situations lorsque plusieurs signaux porteurs 

sont présents, l’évaluation devrait être réduite de 3.5 dB, en particulier lorsque le signal de sortie est ré-émise et peut provoquer des 

interférences adjacentes à la bande utilisateurs. Ce pouvoir est de la réduction par le biais de la sortie d’alimentation ou la réduction de gain 

et non par un atténuateur à la sortie du dispositif.

LIMITED 1 YEAR WARRANTY  |  REGISTER AT WWW.ZBOOST.COM

zBoost warrants every zBoost product to be free from defects in material and workmanship under normal use for the warranty period of 1 year.
Who Is Covered?
You must have proof of purchase to receive warranty service. A sales receipt or other documentation showing the product purchased and the purchase 

date is considered proof of purchase. This limited warranty extends only to the original consumer purchaser or any person receiving the product as a 

gift from the original consumer purchaser and to no other purchaser or transferee. This warranty does NOT extend to commercial users.
What is Covered?
Warranty coverage begins the day you purchase the product. For one year from the original date, the zBoost Cell Phone Signal Booster will be repaired 

or replaced with a new, repaired, refurbished or comparable product (whichever is deemed necessary by zBoost) if it becomes defective or inoperative. 

The exchange will be made without charge to you for parts and labor. You will be responsible for the cost of shipping to the location designated by 

zBoost. If zBoost cannot reasonably repair or replace the unit then zBoost may, at its sole discretion, refund the price you paid for the product. All 

products, including replacement products, are covered only for the original warranty period. When the warranty on the original product expires, the 

warranty on the replacement product also expires.
What is Excluded?
Your warranty does NOT cover:
• Labor charges for set up of the unit.

• Product replacement because of misuse, accident, lightning damage, unauthorized repair or other cause not within the control of zBoost.

• Incidental or consequential damages resulting from the product. Some states do not allow the exclusion of incidental or consequential damages, so

the above exclusion may not apply to you.

• Any modifications or other changes to the product, including but not limited to software or hardware modifications in any way other than as

expressly authorized by zBoost will void this limited warranty.

• Product that has been modified or adapted to enable it to operate in any country other than the country for which it was designed, manufactured,

approved and/or authorized, or repair of products damaged by these modifications.

Make sure you keep…
Please keep your sales receipt or other document showing proof of purchase. Attach it to this Setup Overview and keep both nearby. Also, keep the 

original box and packing material in case you need to return your product.
Before requesting repair service…
Please review the BASE UNIT LED INDICATORS section listed in this overview - This may save you a call.
To get warranty service…
Warranty service will be provided by zBoost. If you believe you need service for your unit, contact zBoost 

 

at 1-800-871-1612 or [email protected]

A representative will go through a diagnostic checklist with you. If it is determined that the product needs to be returned for service or exchanged, you 

will receive a return merchandise authorization (RMA) number. The representative will give you complete shipping details. Do not return products to 

zBoost without a Return Authorization Number (RMA).
To get out of warranty service…
To obtain out of warranty service, contact zBoost at 1-800-871-1612 or [email protected] for information on the possibility of any costs for repair 

or replacement of out-of-warranty products.
Reminder: Record the model and serial number found on the product below:

Model #: 

Serial #: 

Purchase Date: 

WARRANTY INFORMATION

PCS Frequency

CEL Frequency

Frequency

1850 - 1990 MHz

824 - 894 MHz

Band Supported

ALL: A,D,B,E,F & C

ALL: A,B, A’ & B’

Antenna Signal

13 dBi Panel; F-type female

8 dBi Panel; F-type female

Antenna- Base Unit

3 dBi Omni Ceiling Mount

2 dBi Omni Ceiling Mount

Cable Loss

3000 MHz RG-6, approx. 1 dB/10 ft

3000 MHz RG-6, approx. 0.6 dB/10 ft

Both PCS and CEL Frequencies

Network Format

CDMA, GSM, TDMA, AMPS, GPRS, EDGE, EVDO, HSPA, 3G

Base Unit RF Connectors

F-type female and TNC female

Wall Supply Unit

100-240 VAC 50 Hz-60Hz

Power Consumption

3W standby; 7W max signal - 2.0A Max
UL, FCC Parts 15 & 24 (PCS), FCC Parts 15 & 22 (CEL), Industry Canada

Base Unit Size and Weight

5” x 7” x 1.375” - 12 oz.

Base Unit and Power Supply

Indoor Use Only, 5° to 40° C (40° to 105° F)

Coverage (open areas)

4-5 signal bars at the roof antenna; 40’ radius at 360° width per internal antenna;  
3-4 signal bars inside; up to 40,000 sq. ft. 

YXC-40K Product Specifications

System Certifications

At Initial Power Up Only

Solid GREEN

Normal condition at power up.

Slowly Alternating RED and 

GREEN

zBoost is working, but at reduced performance and coverage due to “non-ideal” setup. 
Solution: Increase the distance between Signal Antennas and Base Unit Antenna to achieve maximum performance and 

coverage.

Fast Flashing RED

reduced coverage.
Solution: Increase distance between Base Unit Antenna and Signal Antennas.

Solid RED

System is receiving signal from either the mobile device or the base station transceiver that is too strong for proper operation.
Solutions: 

 Move away from receiving antenna with your cell phone. 

 Move antenna away from other devices.

Fast Alternating RED and 

GREEN followed by no light

Solution: Unplug and start over.

After Initial Power Up

Solid GREEN

Normal condition.

Solid RED

System is receiving signal from either the mobile device or the base station transceiver that is too strong for proper operation.  
Solution: Please unplug your system. Re-orient your Signal Antenna and/or Base Unit Antenna to reduce the excessive signal 

source. Plug your system back in. If still solid red, call customer support 1-800-871-1612.

Base Unit LED Conditions

Reviews: