Operation manual of ZBL-R800, ZBL-R630, ZBL-C310A
Hotline: (86)010-51290405 Fax: (86)010-51290406
56
3.5.2 Introduction of main menu
3.5.2.1 Object No.
Object No. should correspond one by one with tested object. Every
object No. can store up to 13 row × 18 columns, a total of 234
potential values of measuring points.
Object No. can increase automatically. After measurement of a survey
area is complete, go back to main menu, then the object No. will
increase by 1 automatically.
When changing object No. manually, select the “Obj. No.” menu, and
then operate as follows:
1.
Pressing
【
ENTER
】
to enter into object No. adjustment state,
at that time, cursor will occur at the last digit of No.
2.
Pressing
【
a
】
or
【
b
】
to adjust this digit and pressing
【
_
】
or
【
`
】
to select other data bits.
The number adjustment can add or subtract value, the
maximum is 999.
3.
Pressing
【
MENU
】
to go back to menu selection state and
continuing other menu operation.
4.
Pressing
【
BACK
】
to go back to previous state.
3.5.2.2 Test method
Rust test is divided into single-electrode test and double-electrode
test.
Pressing
【
a
】
or
【
b
】
in main menu to move cursor to “Method”
option, pressing
【
ENTER
】
to enter into test method selection menu as
shown in figure3-40, “
”stays on the current test method for
reference. Pressing
【
a
】
or
【
b
】
key to select test method, and
pressing
【
ENTER
】
or
【
SAVE
】