SECTION 4 - INSTALLATION
23
Zator
Via Galvani, 11 - 20095 - Cusano Milanino (MI) - Italy
www.zator.it - [email protected]
4
INSTALLATION
Where possible it is always better to adopt this type of application since it is convenient for both easy
application and to avoid nozzle wear.
The ideal working position of the valve is vertical, with the nozzle facing downwards.
It’s possible to tilt the valve of ±45° degrees (see next page).
The optimal distance between the nozzle and the surface to be glue is between 5 and 10 mm.
Other different positions are possible upon approval of the Zator.
MAX TILT
RECOMMENDED
OPTIMAL DISTANCE
4.1
Fixing of the valve
4.2
Contact-less gluing application
The MZB200 valve must be fixed on a proper bracket
by using the M6 threaded holes machined on the valve
body.
A vibration-free environment and a good accessibility
for regulation, cleaning and maintenance and a good
fixing of the valve to the support/bracket and of the
latter to the machine must be guaranteed.
Threaded
holes M6
± 45°
5 ÷ 10 mm