This symbol indicates that equipment must not be mixed with general household waste. For treatment, recovery and recycling please return to your local designated
WEE/CG0783SS collection point as defined by your local council.
© 2022 System Q Ltd
2
Mortice Mount Mag Lock
Zap is a registered trademark of System Q Ltd
Document ref: qACC512
All specifications are approximate. System Q Ltd reserves the right to change product specifications or features without notice. Whilst every effort is
made to ensure that these instructions are complete and accurate, System Q Ltd cannot be held responsible for any losses, no matter how they arise,
from errors or omissions in these instructions, or the performance or non-performance of the equipment refered to.
button isn't situated next to the door and
a timed released is required.
Mounting
Connections
Troubleshooting
If the door release is not activating the lock then there is likely a shorted wire, open circuit or some
other failed device in the circuit.
To identify where the fault is, each wired connection in the circuit needs to be tested; working from
the door release progress through, including the power supply and the magnetic lock.
If the fault is with the door release then check the connection wires for continuity and for trapped
wires. Check for water ingress on the wired connections. Check the polarity in the power connections
and ensure the connections are connected to the proper terminals.
Specification
ACC512
Design
Mortice Mount
Holding Force
280kg (600lbs)
Delay
No delay (Mimic)
Relay Output
N/A
Voltage
12V DC 440mA / 24V DC 290mA
Construction
Metal Frame
Dimensions
(H) 38 x (W) 230 x (D) 28mm (Lock)