Zap Lighting Monster LED User Manual Download Page 3

 

 

 

 

Monster LED User Manual

  

  

                 

 

 

 

 

Zap Lighting – A brand of  

   

 

 

S

AFETY 

I

NFORMATION

 

 
 

 

 
Respect  all  locally  applicable  laws,  codes  and  regulations  when  installing, 
operating or servicing the fixture. 

 
Protection from electric shock 

Do not expose the fixture to rain or moisture. 
Disconnect the fixture from AC power before carrying out any 
installation or maintenance work and when the fixture is not in use.  
Ensure that the fixture is electrically connected to ground 
(earth). 
Use only a source of AC power that complies with local 
building and electrical codes and has both overload and 
ground-fault (earth-fault) protection. 
Socket outlets or external power switches used to supply the 
fixture with power must be located near the fixture and easily 
accessible so that the fixture can easily be disconnected from 
power. 
Isolate the fixture from power immediately if the power plug or 
any seal, cover, cable, or other component is damaged, 
defective, deformed, wet or showing signs of overheating. Do 
not reapply power until repairs have been completed 
Before using the fixture, check that all power distribution 
equipment and cables are in perfect condition and rated for the 
current requirements of all connected devices. 
Use only Neutrik PowerCon cable connectors to connect to the 
fixture’s power sockets. 
Do not connect devices to power in a chain that will exceed 
the electrical ratings of any cable or connector used in the 
chain. 
The supplied power input cable is rated 32 A and can safely 
supply only one fixture with mains power.  
If you replace this cable must also have three conductors  
18 AWG or 0.75 mm² minimum conductor 
size, have an outer cable diameter of 6 - 15 mm (0.2 - 0.6 in.) 
and be temperature-rated to suit the application. 

 
Protection from burns and fire 

Do not use the fixture to illuminate surfaces within 1000 mm  
of the fixture. 
Operate the fixture with ambient temperature between  
–5° C to + 45° C / 14° F to 113° F.  
The surface of the product casing can reach up to 120° C 
(248° F) during operation. Avoid contact by persons and 
materials. Allow the fixture to cool for at least 15 minutes 

                         WARNING! 

        Read the safety precautions in this manual before 
    Installing, powering, operating or servicing this product. 

 

Summary of Contents for Monster LED

Page 1: ...Monster LED User Manual Rev 02...

Page 2: ...ents SAFETY INFORMATION 3 INTRODUCTION 5 CONTROL FUNCTIONS 6 FEATURES 6 OPERATION 6 PHYSICAL INSTALLATION 7 FASTENING THE FIXTURE TO A FLAT SURFACE 7 MOUNTING THE FIXTURE ON A TRUSS 7 CONNECTIONS 8 PO...

Page 3: ...ntil repairs have been completed Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected device...

Page 4: ...y support If suspending from a rigging structure fasten the fixture to a rigging clamp Do not use safety cables as the primary means of support In case the fixture is hanged up on trellis and its posi...

Page 5: ...instructions given in this manual to ensure the fitting is installed used and serviced correctly and safely Before using the product for the first time 1 Read Safety information on page 3 before insta...

Page 6: ...osition Upright or truss mounted with EZ clamps Primary zoom 34 70 Dimensions including Yoke H 1227 mm x W 802 mm x L 918 mm Stand alone version W o yoke Available Weight Including Yoke VipONE 130 Kg...

Page 7: ...rely If you install the fixture in a location where it may cause injury or damage if it falls install a safety cable Mounting the fixture on a truss The fixture can be clamped to a truss or similar ri...

Page 8: ...Voltage range Fuse protection Power supply transformer 150VA Primary 208 V 230 V Secondary 22 V Power input Input fuse holder FA 16 A 230V Operating power Zone Voltage Connection Electrical Absorptio...

Page 9: ...Zap Lighting A brand of 9 DMX 5 pole socket for connection of a DMX controller After the reset sequence is completed DMX signal connection can be controled by checking the flashing green LED on the di...

Page 10: ...Monster LED User Manual Zap Lighting A brand of 10 DMX chain With extended cable runs the last device in the chain may require a terminating resistor in order to prevent system malfunctions...

Page 11: ...arameters are added the dedicated head DMX parameters It will make a single unique DMX machine From a DMX console Any type of DMX console or controller can control the Monster Led as long as it follow...

Page 12: ...er 6 Brightness CDE Red 7 Red dimmer channel 0 255 Green 8 Green dimmer channel 0 255 Blue 9 Blue dimmer channel 0 255 Cold White 10 Cold White dimmer channel 0 255 Hot White 11 Hot White dimmer chann...

Page 13: ...t from stage effects building structures and fittings or the natural environment at outdoor events for example If one or more of these factors is present inspect fixtures within their first 100 hours...

Reviews: