3
Once the hob has been installed, it is
important to remove any protective materials,
which were put on in the factory.
Hob burners control knobs
The hob burners control knobs are situated on the hob
right hand side. The symbols on the knobs mean that:
there is no gas supply
there is maximum gas supply
there is minimum gas supply
Lighting the burners
For easier lighting, proceed before putting a
pan on the pan support.
Models with semi-automatic ignition
To light a burner, depress the relevant switch
marked with a small spark. Then, push in the
relevant knob and turn it anticlockwise to "maximum
position"
(ZGL 646 I)
.
Models with automatic ignition
Push in the relevant knob and turn it anticlockwise
to "maximum position". After lighting the flame,
keep the knob pushed down for about 5 seconds.
This will allow the "thermocouple" (Fig. 2, lett. D)
to be heated and the safety device to be switched
off, otherwise the gas supply would be interrupted
(ZGL 646 IT - ZXL 636)
.
Then, check the flame is regular and adjust it as
required.
If you cannot light the flame even after several
attempts, check the "cap" (Fig. 1-2, lett. A) is in
the correct position.
To put the flame out, turn the knob to the symbol
z
.
•
Always turn the flame down or put it out before
taking the pans off the burner..
Contents
This appliance complies with the following
E.E.C. Directives:
-
2006/95
(Low Voltage Directive);
-
89/336
(Electromagnetical Compatibility Directive);
-
93/68
(General Directives)
and subsequent modifications.
MANUFACTURER:
ELECTROLUX HOME PRODUCTS ITALY S.p.A.
Viale Bologna, 298
47100 FORLÌ (Italy)
For the User
For the Installer
Instruction for the User
Important Safety Information
2
Instruction for the User
3
Cleaning and Maintenance
5
Technical Data
6
Instruction for the Installer
6
Electrical Connection
7
Adaptation to different types of gas
8
Building In
9
Service and original spare parts
11
Fig. 2
FO 0204
A
- Burner cap
B
- Burner crown
C
- Ignition candle
D
- Thermocouple
"
"
"
"
"
•
"
"
"
"
"
Fig. 1
In the absence of electricity, ignition can occur
without the electrical device; in this case approach
the burner with a flame, push the relevant knob
down and turn it anti-clockwise until it reaches
the"maximum" position.
When switching on the mains, after installation or a
power cut, it is quite normal for the spark generator
to be activated automatically.