10
If after the above checks, there is still a fault, call your local Service Force Centre.
In-guarantee customers should ensure that the above checks have been made as the engineer will make a
charge if the fault is not a mechanical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee service calls.
Symptom
Solution
No power to appliance
The temperature in the freezer is too high
The freezer door will not open
The compressor runs continuously
Excessive frost and ice has built up.
Noise
- Check there is power at the socket.
- Check there is not a power cut by checking the
household lights.
- Check the fuse has not blown.
- Check the thermostat control knob is turned to the
correct setting relative to ambient conditions.
- Check the ambient temperature is within the appliances
operating limits of 10°C to 32°C.
Relocate the appliance if necessary.
- Has door just been opened?
If so leave for a few minutes to allow the air pressure to
equalise.
- Adjust the thermostat control knob to give correct
temperature control. See page 5.
- Check that the door is closed.
- Large quantities of food have recently been placed in
the cabinet and/or door is frequently opened.
- Check that air ventilation is not obstructed.
- Ensure the door is not left open.
- Check that nothing is preventing the door from closing.
Is the door gasket intact and clean?
- Has advised periodic defrosting been carried out?
- Refer to normal operating sounds.
SOMETHING NOT WORKING?
Before
contacting your local Service Force Centre check the following points.
IMPORTANT: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use or
installation, a charge will be made even if the appliance is under guarantee.
Summary of Contents for ZVR 45 R
Page 1: ...FREEZER ZVR 45 R ZVR 45 RN 2222690 98 INSTRUCTION BOOKLET ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 18: ......
Page 19: ......
Page 20: ... Electrolux Household Appliances Limited 2000 ...