TECHNICAL SPECIFICATIONS
Positioning
This appliance should only be installed at a location
where the ambient temperature corresponds to the
climate classification indicated on the rating plate,
which is located on the inside left of the appliance.
The following table shows which ambient temperature
is correct for each climate classification.
SN
+10°C to +32°C
N
+16°C to +32°C
The appliance should be located in a dry atmosphere,
out of direct sunlight and away from continuous heat
and extreme temperature, e.g. not next to a boiler or
radiator, or in a very cold room e.g. an outhouse. If
these temperatures are exceeded i.e. warmer or cold-
er, then the appliance may not operate correctly.
For building-in and door reversal instructions please
refer to the relevant instructions on the following
pages.
INSTALLATION
13
DIMENSIONS
Height
81,5
cm
Width
56
cm
Depth
53,8
cm
POWER SUPPLY VOLTAGE AND FREQUENCY
220-240 V / 50 Hz
TOTAL POWER ABSORBED
100 W
AVERAGE DAILY UNITS ELECTRICITY (*)
0,65 kWh
GROSS CAPACITY
138 l
NET CAPACITY
135 l
(*)This figure is based on standard test results in accordance with European Standard EN153. Actual con-
sumption will depend on how the appliance is used and where it is located.