background image

Installation

During normal operation, the condenser and
compressor at the back of the appliance heat
up considerably. For safety reasons, minimum
ventilation must be as shown in the relevant
Figure.
Attention: keep ventilation openings clear 
of obstruction.

If the appliance is transported horizontally, it is
possible that the oil contained in the
compressor flows in the refrigerant circuit. It is
advisable to wait at least two hours before
connecting the appliance to allow the oil to
flow back in the compressor.

There are working parts in this product which
heat up. Always ensure that there is adequate
ventilation as a failure to do this will result in
component failure and possible food loss.
See installation instructions.

Parts which heat up should not be exposed.
Wherever possible the back of the product
should be against a wall.

If the appliance has been transported
horizontally, it is possible that the oil
contained in the compressor flows in the
refrigerant circuit. It is advisable to wait at
least two hours before connecting the
appliance to allow tlıe oil to flow back in the
compressor.

Environment Protection

This appliance does not contain gasses
which could damage the ozone layer, in
either its refrigerant circuit or insulation
materials. The appliance shall not be
discarded together with the urban refuse
and rubbish. Avoid damaging the cooling
unit, especially at the rear near the heat
exchanger. Information on your local
disposal sites may be obtained from your
municipal authorities. The materials used
on this appliance marked with the symbol

are recyclable.

CONTENTS

GB

Installation

Positioning

Cleaning the interior

Assembly instructions

Door reversal

Instructions for totally built-in
appliances

Electrical connection

Technical specification

Use

Operation 

Temperature regulation 

Fast freezing

Warning light

Internal thermometer

Freezing fresh food

Storage of frozen food 

Thawing

Ice cube production

Defrosting

Maintenance

Periodic cleaning

Extended periods of non-operation

Interior light

Defective operation

36

36

36

36

37

37

38

38

39

39

39

39

39

39

40

40

40

40

41

42

42

42

42

42

35

Summary of Contents for ZPL 7120

Page 1: ...GEFRIERSCHRANK CONGELATEUR KOELKAST FREEZER CONGELATORE ZPL 7120 BEDIENUNGSANLEITUNG MODE D EMPLOI GEBRUIKSAANWIJZING INSTRUCTION BOOKLET ISTRUZIONIPERL USO 2222 192 14 ...

Page 2: ...refrigerating appliances unless they are approved for this purpose by the manufacturer Service Repair Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person This appliance should be serviced by an authorized Service Centre and only genuine spare parts should be used Under no circumstances should you attempt to repair the applianc...

Page 3: ...e refrigerant circuit It is advisable to wait at least two hours before connecting the appliance to allow tlıe oil to flow back in the compressor Environment Protection This appliance does not contain gasses which could damage the ozone layer in either its refrigerant circuit or insulation materials The appliance shall not be discarded together with the urban refuse and rubbish Avoid damaging the ...

Page 4: ...Manufacturer declines all responsibility if the above safety precautions are not observed This appliance complies with EEC directive number 87 308 of 2 6 87 relative to radio interference suppression This appliance complies with the following E E C Directives 73 23 EEC of 19 2 73 Low Voltage Directive and subsequent mod fications 89 336 EEC of 3 5 89 Electromagnetic Compatibility Directive and sub...

Page 5: ...2 200 200 cm 2 min D567 Door reversal Right hand door opening Remove the upper and lower screws 1 and pivots 2 with the safety washer 4 on the left side Fig 2 Remove the door stop hinge 3 Fig 3 Left hand door opening Remove the upper right screw and pivot Straighten the safety washer 4 of the lower right hinge Remove the screw 5 and the pivot ó Fig 3 For safety reasons bend the washer located unde...

Page 6: ...technical data is indicated in the rating plate on the left side inside the appliance GB Air is taken in through the ventilation grille at the bottom of the appliance but an air outlet gap measuring 50 mm deep by 540 mm wide Fig 6 must be provided in the rear of the kitchen unit This outlet gap must also be kept clear between the top of the unit and the ceiling Slide the refrigerator into the unit...

Page 7: ... exact setting should be chosen keeping in mina that the temperature inside the refrigerator depends on room temperature how often the door is opened the quantity of food stored location of appliance A medium setting is generally the most suitable To stop operation simply turn the thermostat knob to position 0 Fast freezing To start fast freezing food press button B Pilot light C will come on Warn...

Page 8: ... freeze top quality fresh and thoroughly cleaned foodstuffs Prepare the fresh food in small portions to enable it to be rapidly and completely frozen and to make it possible subsequently to thaw only the quantity required at the time Wrap up the food in aluminium foil or polythene and make sure that the packages are airtight It is advisable to show on the single food packet or on the write on prod...

Page 9: ...ck on the inner liner complete defrosting should be carried out as follows pull out the plug from the wall socket or turn the thermostat knob to the O setting remove any stored food wrap it in several layers of newspaper and put it in a cool piace leave the door open and insert the plastic scraper in the appropriate seating at the bottom centre placing a basin underneath to collect the defrost wat...

Page 10: ...er s efficiency Extended periods of non operation Whenever the freezer is not to be used for an extended period of time disconnect it from the wall socket and empty and clean the freezer Remember to leave the door open for the entire period of time in which the freezer is not to be used MAINTENANCE GB DEFECTIVE OPERATION GB Before calling your local dealer for servicing assistance check the follow...

Reviews: