ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.
CONNECTING THE TERMINAL BOARD
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
cable to the terminal. After you connect the supply
cable to the terminal board, attach it with a junction
clamp.
3N ~
2N ~
230V ~
230V ~
230V ~
230V ~
1
2
3
5
4
1
2
3
5
4
1
2
3
5
4
ENERGY EFFICIENCY
PRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014
Supplier's name
Zanussi
Model identification
ZOU30601XU
Energy Efficiency Index
100.0
Energy efficiency class
A
Energy consumption with a standard load, conventional
mode
0.93 kWh/cycle
Energy consumption with a standard load, fan-forced mode
0.85 kWh/cycle
Number of cavities
1
Heat source
Electricity
Volume
72 l
Type of oven
Built-Under Oven