31
Electrical Connection
The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block
which is marked as follows:
Letter L -
Live terminal
Letter N-
Neutral terminal
or E-Earth terminal
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the electrical
supply must comply to the specifications given
below.
It is necessary that you install a double pole switch
between the oven and the electricity supply (mains),
with a minimum gap of 3mm between the switch
contacts and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and green
earth cable at any point.
the yellow and green earth cable should be 2-3 cm
longer than the other cables.
Important
After installation and connecting, the cable must be
placed so that it cannot at any point reach a
temperature of more than 50°C above the ambient
temperature.
Before the oven is connected, check that the main
fuse and the domestic installation can support the
load and that the power supply is properly earthed.
The manufacturer declines any responsibility
should these safety measures not be carried
out.
For Europe use only
Min. size Cable/
Cable / flex type
Fuse
flex
2.5 mm
2
H07 RN-F, H05 RN-F, 15 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
Connection
Min. size
Cable / flex Fuse
via
Cable/flex type
13 A socket
2.5 mm
2
3 core
13 A min.
outlet
butyl
13 A spur box
insulated
Oven
2.5 mm
2
PVC/PVC
15 A min.
Control
twin and
Circuit
earth
20 A max.
For UK use only
Summary of Contents for ZOB 550
Page 1: ...1 ZOB 550 User Manual Built in Oven ...
Page 35: ...35 ...
Page 36: ...36 35699 2102 05 08R A www zanussi electrolux co uk ...