166
Installation dimensions
The opening in the cabinet must correspond to the
standard dimensions. The necessary information can
be found in the dimensional sketch.
·
The separation between the lower surface of the
hob and the parts of the furniture below it must be
at least
20 mm
.
·
The lateral separation between the sides of the
hob and the cabinet must be at least
50 mm,
and
must be at least
50 mm
from the rear panel.
This appliance conforms to Type Y (IEC 335--2--6)
with regard to fire protection. Only appliances of
this type may be installed on one side of adjacent
cabinets or walls.
Installation
1.
Cut out the worktop according to the prescribed di-
mensions
(Fig.1).
(Saw exactly along the scribed
line.)
2.
Fix according to
Fig. 2
Position
A
must be used for screwing--on the catch
springs
(Fig.1).
Important:
The screw must be driven into the worktop
as illustrated.
Avoid overtightening. Do not use electric or pneumatic
screwdrivers unless they have, adjustable slipping
clutches (set to 1--1.1 Nm).
3.
Check the sealing for proper fit and full contact.
4.
Place the ceramic hob in the cut--out.
Removing the glass--
ceramic hob
1.
Disconnect the appliance from the electrical sup-
ply.
2.
Push the hob upwands from underreath.
min. 50 mm
min. 50 mm min. 50 mm
20 mm
20 mm
Fig.1
R5
Fig.2
8
4 Frame
5 Sealing tape
6 Glass ceramic plate
1 Catch spring
2 Screws
3 Worktop
Summary of Contents for ZKT 662 LN