13
GB
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
• n. 1 bag with screws for fixing the frame to the ceiling-buttress
1
• n. 1 bag with screws for fixing the chimney stack to the hood canopy
2
• n. 1 bag with screws for fixing the connection box
3
• n. 1 bag containing documents.
Instructions for installation
To facilitate installation, proceed in the order indicated below:
• Installing the Frame.
• Ducting or recirculation fitting.
• Connection to the mains power supply.
• Fitting the telescopic chimney.
• Electrical connection and testing.
• Fitting the hood canopy
Installing the Frame
The frame is suitable for fixing to the ceiling or to a
wooden buttress of suitable thickness, which must
be firmly anchored to the ceiling or to other bearing
structures.
• Using a plumb line or similar tool, identify and mark
the centre on the ceiling or buttress, starting from the
centre of the cooking appliance.
• Use the cardboard template provided to mark the
ceiling or wooden buttress, making sure that the
centres coincide and lining up one of the two axes (A
or B) of the template so that it is parallel with the long
side of the cooking appliance.
• Mark the position of the 4 fixing holes indicated on
the drilling template.
• Drill the holes as follows:
- Ceiling: 4 holes Ø 10 mm to fix the frame in position;
- Buttress: 4 holes Ø 8 mm to fix the frame in position.
Fixing to the Ceiling
Attention: Due to the many differing types of ceiling
construction, the choice of fixings is left to the
discretion of the installer. It is necessary to emphasise
that the fitting has to be absolutely accurate because
of the weight of the cooker hood and because of the
flexing caused by accidental lateral stresses on the
appliance. Only the following types of ceiling are
suitable for installing the Island cooker hood:
• Solid concrete ceiling: use dowels for concrete, not supplied.
• Solid wooden buttress ceiling: use Ø 10 mm wood screws with a minimum length of 120
mm, not supplied.
• Cavity ceiling with inner space, having a wall thickness of about 20 mm; use, in this case
only, the 4 dowels and screws supplied in bag (1). Once fixed, make sure that the base
is absolutely stable, even when the metal frame is subjected to lateral stress. In all other
TS
TI
4324665 01 - 001201