15
GB
RECIRCULATION VERSION AIR OUTLET
• Push fit the air outlet fitting
15
onto the air outlet
of the hood body.
• Ensure that the activated charcoal filters have
been inserted.
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch
having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance)
being sure that the connector of the feeding cable is
correctly inserted in the socket placed on the side of the
fan.
Flue assembly
Upper exhaust flue
• Slightly widen the two sides of the upper flue
and hook them behind the brackets
7.2.1
,
making sure that they are well seated.
• Secure the sides to the brackets using the 4
screws
12c
(2,9 x 9,5) supplied.
Lower exhaust flue
• Slightly widen the two sides of the flue and hook
them between the upper flue and the wall,
making sure that they are well seated.
• Fix the lower part laterally to the hood body
using the 2 screws
12c
(2,9 x 9,5) supplied.
• Make sure that the air outlet connection is
aligned with the chimney outlets.
15
1
12e
2.1
2.2
2
7.2.1
12e