background image

14

Extraction (Ducted)

The cooker hood is more effective when installed in the 
extraction mode (ducted to the outside).

Venting kits may be purchased through your retailer 
or DIY store or using the enclosed form, and must be 
evacuated through an outside vent of ø125 (5ins) or 
ø150mm (6ins).

The ducting used must be manufactured from fire 
retardent material conforming to the relevant British 
Standard or DIN 4102-B1.

When the cooker hood is ducted to the outside the 
charcoal fi lter must be removed.

 

 Fitting 

the 

Ducting

•  Fit the ø150mm (6ins) ducting to the spigot on 

top of the hood body as illustrated.

•  When using ø125mm (5ins) ducting fi t 

item 9

 

and 

10

 on to the spigot on the top of the hood 

body as illustrated.

•  For the best performance use the shortest 

possible run of ducting and we recommend the 
use of rigid pipe in preference to fl exible hose 
as this will improve the fl ow of air while reducing 
turbulence, which causes causes noise and a 
loss of performance.

•  If the room where the cooker hood is to be used 

contains a fuel burning appliance such as a 
central heating boiler, then its fl ue must be be of 
the room sealed or balanced fl ue type.

•  If other types of fl ue or appliances are fi tted 

ensure that there is an adequate supply of air to 
the room.

•  The cooker ducting when fi tted in the 

evacuation mode must never be connected to 
central heating fl ues, radiators or water heaters.

Recirculation Mode

The cooker hood is supplied specifi ed for use in the 
recirculation mode, with the charcoal fi lter fi tted. 

In the recirculation mode contaminated air is passed 
through the charcoal fi lter to be purifi ed and recirculated 
into the kitchen through the grille outlets on either side 
of the chimney.

•  Push fi t the air outlet connector 

item 15

 onto onto 

the air outlet.

•  Ensure the activated charcoal fi lter has been fi tted.

INSTALLING THE COOKER HOOD

9

ø 125

10

ø 150

15

Summary of Contents for ZHC 605

Page 1: ...COOKER HOOD ZHC605 ZHC705 ZHC905 INSTRUCTION BOOKLET...

Page 2: ...omplete and return the guarantee card supplied with the appliance For the User Important Safety Information Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extracti...

Page 3: ...cool The cut out device will reset itself when the fan motor has cooled signi cantly It is dangerous to alter the speci cations or modify this product in any way When installed between adjoining wall...

Page 4: ...d Controls The cooker hood functions are controlled by three switches located on the underside of the hood immediately in front of the metal grease lters Worktop Lighting The switch L marked with the...

Page 5: ...the grease lters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start...

Page 6: ...water when cleaning particularly around the control panel Metal Grease Filters The grease lters absorb grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned a...

Page 7: ...osition This appliance can be a possible re hazard if the grease and charcoal lters are not cleaned and replaced as recommended Changing the Light Bulb 1 Remove the screw fastening the lamp cover 2 Ro...

Page 8: ...e entry of fresh air If set up for recirculation check that the charcoal lter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device h...

Page 9: ...tic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those whi...

Page 10: ...ELECTRICAL CONNECTIONS Electrical Requirements Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this sho...

Page 11: ...nt person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling...

Page 12: ...red when installed above a slot in electric cooker or 787mm 30 1 2 when installed above a slot in gas cooker When installed between adjoining wall cabinets the wall cabinets must not overhang the hob...

Page 13: ...l must be tted before xing the hood body and if it is to be xed at both top and bottom must be tted at the correct height prior to installing the bases As this operation is rather complex it should be...

Page 14: ...eference to exible hose as this will improve the ow of air while reducing turbulence which causes causes noise and a loss of performance If the room where the cooker hood is to be used contains a fuel...

Page 15: ...ews item 12c 2 9 x 9 5mm supplied Fitting the Lower Chimney Slightly widen the two sides of the lower chimney and hook them between the upper chimney and the wall ensuring they are correctly seated Fi...

Page 16: ...Electrolux plc 2002 436002529_01 050121...