A
B
C
D
A. End of shaft with nut
B. Washer supplied with the appliance
C. Elbow supplied with the appliance
D. Rubber pipe holder for liquid gas
Liquid gas
Use the rubber pipe holder for liquid gas. Always
engage the gasket. Then continue with the gas
connection.
The flexible pipe is prepared for apply when:
• it can not get hot more than room temperature,
higher than 30°C;
• it is no longer than 1500 mm;
• it shows no throttles;
• it is not subject to traction or torsion;
• it does not get in touch with cutting edges or
corners;
• it can be easily examined in order to make sure
its condition.
The control of preservation of the flexible pipe
consists in checking that:
• it does not show cracks, cuts, marks of burnings
on the two ends and on its full length;
• the material is not hardened, but shows its
correct elasticity;
• the fastening clamps are not rusted;
• expired term is not due.
If one or more defects are visible, do not repair the
pipe, but replace it.
WARNING! When installation is
complete, make sure that the seal of
each pipe fitting is correct. Use a
soapy solution, not a flame!
ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
WARNING! Make sure the flame does
not go out when you quickly turn the
knob from the maximum position to the
minimum position.
ELECTRICAL CONNECTION
• Make sure that the rated voltage and type of
power on the rating plate agree with the voltage
and the power of the local power supply.
• This appliance is supplied with a mains cable
and a plug.
• Always use a correctly installed shockproof
socket.
• Make sure that there is an access to the mains
plug after the installation.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• There is a risk of fire when the appliance is in
connection with an extension cable, an adapter
or a multiple connection. Make sure that the
ground connection agrees with the standards
and regulations.
• Do not let the power cable to heat up to a
temperature higher than 90° C.
Make sure that you connect the blue
neutral cable to the terminal with a
letter "N" on it. Connect the brown (or
black) phase cable to the terminal
which has a letter "L". Keep the phase
cable connected at all times.
CONNECTION CABLE
To replace the connection cable use only the
special cable or its equivalent. The cable type is:
H05V2V2-FT90.
Make sure that the cable section is applicable to
the voltage and the working temperature. The
yellow / green earth wire must be approximately 2
cm longer than the brown (or black) phase wire.
11