Adaptation to different types of gas
A. Injectors replacement
• Remove the pan supports.
• Remove the burner's caps and
crowns.
• With a socket spanner 7 unscrew
and remove the injectors (Fig. 2), and
replace them with the ones required
for the type of gas in use.
• Reassemble the parts, following the
same procedure backwards.
• Replace the rating label (placed near
the gas supply pipe) with the relevant
one for the new type of gas supply.
You can find this label in the package
of the injectors supplied with the
appliance.
Should the feeding gas pressure be
different or variable compared with
the required pressure, an
appropriate pressure adjuster must
be fitted on the gas supply pipe, in
compliance with the rules in force.
B. Adjustment of
minimum level
To adjust the minimum level of the
burners, proceed as follows:
• Light the burner.
• Turn the knob on the minimum
position.
• Remove the knob.
• With a thin screwdriver, adjust the
by-pass screw (Fig. 3). If changing
from natural gas to LPG, completely
tighten clockwise the screw, until a
small regular flame is obtained.
• Finally check the flame does not go
out when quickly turning the knob
from the maximum position to the
minimum position.
This procedure can easily be carried
out, anyhow the hob has been
positioned or built in the working top.
)
Fig. 2
Fig. 3
by-pass screw
by-pass screw
)