Zanussi ZGL 62 ITX Instruction Booklet Download Page 9

9

Important safety requirements

650 mm

400 mm

400 mm

100 mm

50 mm

50 mm

55 mm

600 mm

700 mm

400 mm

100 mm

400 mm

50 mm

55 mm

50 mm

I

CLEARANCES REQUIRED

 WHEN FITTING THE HOB

WITHOUT A COOKER HOOD ABOVE

CLEARANCES REQUIRED

WHEN FITTING THE HOB

WITH A COOKER HOOD ABOVE

FO 0813

FO 0812

700 mm

This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current Edition)
and the IEE Wiring Regulations (Current Edition).
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813 Current
Editions and the ETCI Rules for Electrical Installations.

Provision for ventilation

Detailed recommendations are contained in the following
British Standards Codes Of Practice: B.S. 6172/ B.S.
5440, Part 2 and B.S. 6891 Current Editions.
The hob should not be installed in a bed sitting room
with a volume of less than 20 m

3

. If it is installed in a

room of volume less than 5 m

3

 an air vent of effective

area of 110 cm

2

 is required. If it is installed in a room of

volume between 5 m

3

 and 10 m

3

 an air vent of effective

area of 50 cm

2

 is required, while if the volume exceeds

11 m

3

 no air vent is required.

However, if the room has a door which opens directly to
the outside no air vent is required even if the volume is
between 5 m

and 11 m

3

.

If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland please
refer to the NSAI- Domestic Gas Installation I.S. 813
Current Editions Table Four.

Location

The hob may be located in a kitchen, a kitchen/diner or
bed sitting room, but not in a bathroom, shower room or
garage.
Before making the cut out in the worktop ensure that
there is a minimum distance of 55 mm between the rear
edge of the hob and the wall.
A minimum distance of 100 mm must be left between
the side edges of the hob and any adjacent cabinets or
walls.
The minimum distance combustible material can be fitted
above the hob in line with the edges of the hob is 400
mm. If it is fitted below 400 mm a space of 50 mm must
be allowed from the edges of the hob.
The minimum distance combustible material can be fitted
directly above the hob is 700 mm.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S 813 Current
Edition Section 7- Permitted Locations of Appliance.

Summary of Contents for ZGL 62 ITX

Page 1: ...GAS HOB ZGL 62 ITX INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB IE ...

Page 2: ...re that they can use the appliance safely During Use z This hob is intended for domestic cooking only It is not designed for commercial or industrial purposes z When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose z Whe...

Page 3: ...ated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information a...

Page 4: ...4 Description of the Hob 1 HobTop 2 Auxiliary Burner 3 Semi rapid Burners 4 Rapid Burner 5 Control knobs 6 Electric Ignition Push Button 1 3 2 3 4 5 6 ...

Page 5: ...ven after several attempts check the cap and crown see diagram letterA and B are in the correct position To put the flame out turn the knob to the symbol z When switching on the mains after installation or a power cut it is quite normal for the spark generator to be activated automatically To ensure maximum burner efficiency you should only use pots and pans with a flat bottom fitting the size of ...

Page 6: ... cleaner For other hobs use Hob Brite or Bar Keepers Friend Pan Supports Thepansupportsaredishwasherproof Ifwashingthem by hand take care when drying them as the enamelling process occasionally leaves rough edges If necessay remove stubborn stains using a paste cleaner The Burners Theburnercapsandcrownscanberemovedforcleaning Washtheburnercapsandcrownsusinghotsoapywater and remove marks with a mil...

Page 7: ...he appliance is under guarantee SYMPTOM There is no spark when lighting the gas The gas ring burns unevenly SOLUTION Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped if fitted Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly e g after cleaning Check the main jet is not blocked and the burner...

Page 8: ...ug fitted with a 3 amp cartridge fuse BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 2 0 0 45 1 0 0 33 NOMINALFLOW RATE m3 h 0 286 0 062 0 190 0 043 0 095 0 031 NOZZLEREFERENCE 119 Adjust 96 Adjust 70 Adjust NOMINALTHERMAL POWER kW 2 8 0 65 2 0 0 45 1 0 0 33 NOMINALFLOW RATE g h 202 47 144 32 72 24 NOZZLEREFERENCE 86 40 71 32 ...

Page 9: ...volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements For appliances installed in the Republic of Ireland please...

Page 10: ...PORTANT This hob must be installed by a competent person to the relevant Gas Standards Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed it is important to remove any protective materials which were put on in the factory Any gas installation must be carried out by a compe...

Page 11: ...pboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface Building over a kitchen unit with door Proper arrangements must be taken in designing the furniture unit in order to avoid any contact with the bottom of the hob which can be heated when it is operated The recomm...

Page 12: ...wn Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there mus...

Page 13: ...hat the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence of burning around the fault START Isolate appliance and ...

Page 14: ... burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insulation ...

Page 15: ... hob Commissioning When the hob has been fully installed it will be necessary to check the minimum flame setting To do this follow the procedure below Turn the gas tap to the MAX position and ignite Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times If the flame is unstable or is extinguished follow the procedure below Procedure Re ignite the burner ...

Page 16: ...thin a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux Service and Spare Parts In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local Service Force Centre by telephoning 0870 5 929 929 Your telephone call will be automatically routed to the Ser...

Page 17: ...of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of residence for this particular model or range of appliances The appliance guarantee is personal to the original purchaser of the appliance and cannot be transferred to another user The appliance is installed and used in accordance with instructions issued by E...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...Grafiche MDM Forlì 35687 8002 11 06 www zanussi electrolux co uk ...

Reviews: