background image

Choose fixed connections or use a flexible pipe in

stainless steel in compliance with the regulation in

force. If you use flexible metallic pipes, be careful

they do not come in touch with mobile parts or they

are not squeezed. Also be careful when the hob is

put together with an oven.

Make sure that the gas supply

pressure of the appliance obeys the

recommended values. The adjustable

connection is fixed to the

comprehensive ramp by means of a

threaded nut R 1/2". Screw the parts

without force, adjust the connection in

the necessary direction and tighten

everything.

A

B C

A. End of shaft

B. Washer supplied with the appliance

C. Elbow supplied with the appliance

Liquid gas

Use the rubber pipe holder for liquid gas. Always

engage the gasket. Then continue with the gas

connection.
The flexible pipe is prepared for apply when:
• it can not get hot more than room temperature,

higher than 30°C;

• it is no longer than 1500 mm;

• it shows no throttles;

• it is not subject to traction or torsion;

• it does not get in touch with cutting edges or

corners;

• it can be easily examined in order to make sure

its condition.

The control of preservation of the flexible pipe

consists in checking that:
• it does not show cracks, cuts, marks of burnings

on the two ends and on its full length;

• the material is not hardened, but shows its

correct elasticity;

• the fastening clamps are not rusted;

• expired term is not due.
If one or more defects are visible, do not repair the

pipe, but replace it.

WARNING! When installation is

complete, make sure that the seal of

each pipe fitting is correct. Use a

soapy solution, not a flame!

INJECTORS REPLACEMENT
1. 
Remove the pan supports.

2. Remove the caps and crowns of the burner.

3. With a socket spanner 7 remove the injectors

and replace them with the ones which are

necessary for the type of gas you use (see

table in "Technical Data" chapter).

4. Assemble the parts, follow the same procedure

backwards.

5. Replace the rating plate (it is near the gas

supply pipe) with the one for the new type of

gas supply. You can find this plate in the

package supplied with the appliance.

If the supply gas pressure is changeable or

different from the necessary pressure, you must fit

an applicable pressure adjuster on the gas supply

pipe.

ADJUSTMENT OF MINIMUM LEVEL
To adjust the minimum level of the burners:
1. Light the burner.

2. Turn the knob on the minimum position.

3. Remove the knob . 

4. With a thin screwdriver, adjust the bypass

screw position (A).

A

5. If you change:

• from natural gas G20 20 mbar to liquid gas,

fully tighten the bypass screw in.

• from liquid gas to natural gas G20 20 mbar,

undo the bypass screw approximately 1/4

of a turn (1/2 of a turn for Triple Crown

burner).

WARNING! Make sure the flame does

not go out when you quickly turn the

knob from the maximum position to the

minimum position.

6

Summary of Contents for ZGG66424XA

Page 1: ...GETTING STARTED EASY User Manual ZGG66424XA EN User Manual Hob EG ...

Page 2: ...sons with very extensive and complex disabilities shall be kept away unless continuously supervised Children of less than 3 years of age should be kept away unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible p...

Page 3: ... you route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more than 50 C above room temperature WARNING Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the manufacturer of the appliance in the instructions for use as suitable or hob guards incorporate...

Page 4: ... plug after the installation If the mains socket is loose do not connect the mains plug Do not pull the mains cable to disconnect the appliance Always pull the mains plug Use only correct isolation devices line protecting cut outs fuses screw type fuses removed from the holder earth leakage trips and contactors The electrical installation must have an isolation device which lets you disconnect the...

Page 5: ...ample vinegar lemon juice or limescale remover touch the hob This can cause matt patches Discoloration of the enamel or stainless steel has no effect on the performance of the appliance CARE AND CLEANING WARNING Do not remove the buttons knobs or gaskets from the control panel Water may get inside the appliance and cause damage Clean the appliance regularly to prevent the deterioration of the surf...

Page 6: ...but shows its correct elasticity the fastening clamps are not rusted expired term is not due If one or more defects are visible do not repair the pipe but replace it WARNING When installation is complete make sure that the seal of each pipe fitting is correct Use a soapy solution not a flame INJECTORS REPLACEMENT 1 Remove the pan supports 2 Remove the caps and crowns of the burner 3 With a socket ...

Page 7: ...connection with an extension cable an adapter or a multiple connection Make sure that the ground connection agrees with the standards and regulations Do not let the power cable to heat up to a temperature higher than 90 C Make sure that you connect the blue neutral cable to the terminal with a letter N on it Connect the brown or black phase cable to the terminal which has a letter L Keep the phase...

Page 8: ...he hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door min 20 mm max 150 mm 30 mm 60 mm B A A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit 8 ...

Page 9: ... Semi rapid burner 2 Triple Crown burner 3 Auxiliary burner 4 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters 9 ...

Page 10: ...shed for more than 15 seconds If the burner does not light after 15 seconds release the control knob turn it into off position and try to light the burner again after minimum 1 minute CAUTION In the absence of electricity you can ignite the burner without electrical device in this case approach the burner with a flame turn the control knob counter clockwise to maximum gas supply position and push ...

Page 11: ...IAMETERS OF COOKWARE Use cookware with diameters applicable to the size of burners Burner Diameter of cook ware mm Triple Crown 180 260 Semi rapid front 120 180 Semi rapid rear 120 220 Auxiliary 80 160 CARE AND CLEANING WARNING Refer to Safety chapters GENERAL INFORMATION Clean the hob after each use Always use cookware with a clean base Scratches or dark stains on the surface have no effect on ho...

Page 12: ...hem carefully before you put them back on CLEANING THE SPARK PLUG This feature is obtained through a ceramic ignition candle with a metal electrode Keep these components well clean to prevent difficult lighting and check that the burner crown holes are not obstructed PERIODIC MAINTENANCE Speak to your local Authorised Service Centre periodically to check the conditions of the gas supply pipe and t...

Page 13: ...g by a service technician or dealer will not be free of charge also during the warranty period The instructions about the Service Centre and conditions of guarantee are in the guarantee booklet LABELS SUPPLIED WITH THE ACCESSORIES BAG Stick the adhesive labels as indicated below MOD PROD NO SER NO DATA MOD PROD NO SER NO DATA MOD PROD NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it o...

Page 14: ...ce cate gory II2H3 Gas connec tion R 1 2 Appliance class 3 GAS BURNERS FOR NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Triple Crown 4 0 1 4 146 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Triple Crown 4 0 1 4 98 291 286 S...

Page 15: ...tainers to recycle it Help protect the environment and human health by recycling waste of electrical and electronic appliances Do not dispose of appliances marked with the symbol with the household waste Return the product to your local recycling facility or contact your municipal office 15 ...

Page 16: ...WWW ZANUSSI COM SHOP 867329568 C 392018 ...

Reviews: