32
Replacing the injectors
1. Remove the pan supports.
2. Remove the burner caps and crowns.
3. Using a 7 mm socket spanner
unscrew
and remove the injectors
,
then replace
them with the ones required for the new
type of gas
(see the table “Burner
characteristics”).
4.
Reassemble the parts, following the
same procedure backwards.
5. Replace the Gas Type Label (located
near the gas supply connection) with the
one corresponding to the new type of
gas. The label is supplied in the
accessories plastic bag.
Should the feeding gas pressure be different
or variable compared with the required
pressure, an appropriate pressure regulator
must be fitted on the gas supply pipe, in
compliance with the rules in force.
Conversion to LPG
GAS
BURNER
INJECTOR
NOMINAL
REDUCED
NOMINAL
FEEDING
TYPE
TYPE
REFERENCE
THERMAL
THERMAL
FLOW RATE PRESSURE
1/100 mm
POWER
POWER
kW
kW
m3/h
g/h
mbar
Rapid
119
2.9
0.65
0.276
Semirapid
96
1.9
0.45
0.181
-
20
Auxiliary
70
1.0
0.33
0.095
-
Rapid
86
2.7
0.65
-
196
Semirapid
71
1.9
0.45
-
138
28-30/37
Auxiliary
50
1.0
0.33
-
73
NATU-
RAL
GAS
(G20)
LIQUID
GAS
(Butane/
Propane)
Burner characteristics