background image

6

Zanussi Guarantee conditions

We, Zanussi, undertake that if, within 24 months of the

date of the purchase, this Zanussi appliance or any part

thereof is proved to be defective by any reason only of

faulty workmanship or materials, we will, at our option,

repair or replace the same FREE OF ANY CHARGE for

labour, materials or carriage on condition that:
* The appliance has been correctly installed and used

only on the gas and electricity supply stated on the

rating plate.

* The appliance has been used for normal domestic

purpose  only,  and  in  accordance  with  the

manufacturer's instructions.

* The appliance has not been serviced, maintained,

repaired, taken apart or tampered with by any person

not authorised by us.

* All service work under this guarantee must be

undertaken by a Zanussi Service Centre.

* Any appliance or defective part replaced shall

become the Company's property.

* This guarantee is in addition to your statutory and

other legal rights.

Home visits are made between 

8.30am and 5.30pm

Monday to Friday

.

 Visits may be available outside these

hours, in which case a 

premium 

will be charged.

Exclusions

This guarantee does not cover:

* Damage or calls resulting from transportation,

improper use or neglect, the replacement of any light

bulbs or removable parts of glass or plastic.

* Costs incurred for calls to put right an appliance

which is improperly installed or calls to appliance

outside the United Kingdom.

* Appliances found to be in use within a commercial

or similar environment, plus those which are the

subject to rental agreements.

* Products of Zanussi manufacture which are not

marketed by Zanussi.

European Guarantee

If you should move to another country within Europe then

your guarantee moves with you to your new home

subject to the following qualifications:

* The  guarantee  starts  from  the  date  you  first

purchased your product.

* The guarantee is for the same period and to the same

extent for labour and parts as exist in the new country

of use for this brand or range of products.

* This  guarantee  relates  to  you  and  cannot  be

transferred to another user.

* Your new home is within the European Community

(EC) or European Free Trade Area.

* The product is installed and used in accordance with

our instructions and is only used domestically, i.e. a

normal household

* The  product  is  installed  taking  into  account

regulations in your new country.

Before you move, please contact your nearest Customer

Care centre, listed below, to give them details of your

new home. They will then ensure that the local Service

Organisation is aware of your move and able to look after

you and your appliances.
France

Senlis

+33 (0)3 44 62 29 99

Germany

Nürnberg

+49 (0)911 323 2600

Italy

Por39 (0)1678 47053

Sweden

Sto46 (0)8 738 79 50

UK

Slough

+44 (0)1753 219897

Guarantee Conditions

For general enquiries concerning your Zanussi appliance

or for further information on Zanussi products, please

contact  our  Customer  Care  Department  by  letter  or

telephone at the address below or visit our website at

www.zanussi.co.uk

Customer Care Department

Zanussi

55-77 High Street

Slough

Berkshire

SL1 1DZ

08705 727727 (*)

*  calls  to  this  number  may  be  recorded  for  training

purposes.

Customer Care Department

Summary of Contents for ZGG 642

Page 1: ...GAS HOBS ZGG 642 ZGG 752 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB ...

Page 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Page 3: ... Service and Spare Parts 5 Guarantee conditions 6 Important safety requirements 10 Installation 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 Description of the Hob 1 1 Semi rapid Burners 2 Rapid Burner 3 Auxiliary Burner 4 Control knobs 1 2 3 4 2 1 3 1 1 4 ZGG 642 ZGG 752 ...

Page 4: ... been added Avoid the use ofthefollowing household detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers Should the hob top become heavily soiled it is recommendedthatacleaningproductsuchasHobBrite or Bar Keepers Friend is used Pan Supports The pan supports are dishwasher proof If necessary remove stubborn stains using a paste cleaner N...

Page 5: ...does not operate correctly contact your local Service Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown In the event of your appliance requiring service or if you wish t...

Page 6: ...hose which are the subject to rental agreements Products of Zanussi manufacture which are not marketed by Zanussi European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications The guarantee starts from the date you first purchased your product The guarantee is for the same period and to the same ex...

Page 7: ...N SALES Shetland ZE1 0PW SHETLAND Bolts Shetland Ltd 26 North Road Lerwick OWN SALES Shetland ZE1 0PE WHALSAY Leask Electrical Harisdale Symbister Whalsay OWN SALES Shetland ZE2 9AA NORTHERNIRELAND BELFAST Owenmore House M27 Kilwee Business Park Upper Dunmury Lane Belfast BT17 0HD WALES CARDIFF Guardian Industrial Estate M28 Clydesmuir Road Tremorfa Cardiff CF2 2QS CLYWD Unit 6 7 Coed Parc M14 Abe...

Page 8: ...ELD 284 Alma Road M49 Enfield London EN3 7BB GRAVESEND Unit B4 M57 Imperial Business Estate Gravesend Kent DA11 0DL HARPENDEN Unit 4 M46 Riverside Estate Coldharbour Lane Harpenden AL5 4UN LETCHWORTH 16 17 Woodside Ind Estate M50 Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane M76 Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road M60 Maidenhead Berkshire SL6 8BY MOLESEY 10 I...

Page 9: ...n HT Spark Spark Generator Ispra Control s BF 50046 230 240V 0 6 YA T 120 Spark Gap Fixed Semi rapid Burner Heat Input 1 9 kW 6483 BTU HR Rapid Burner Heat Input 2 9 kW Natural Gas 9895 BTU HR 2 7 kW L P G 9212 BTU HR Auxiliary Burner Heat Input 1 0 kW 3412 BTU HR BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 2 9 0 65 1 9 0 45 1 0 0 3...

Page 10: ...all have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob The minimum distance combustible material can be fitted directly above the hob is 700 mm Aminimum distance of 100 mm must be left between the side edges o...

Page 11: ...nit in order to avoid any contact with the bottom of the hob which can be heated when it is operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Fitting the hob to the worktop Before fitting the hob into the cut out an...

Page 12: ...and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there must be no cut or stray stran...

Page 13: ...ss than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal eviden...

Page 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 15: ...ading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensure that the gas taps are in the OFF posi...

Page 16: ...e Electrolux Group The world s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...