background image

7

OVERALL DIMENSIONS

Width:

680 mm

Depth:

510 mm

CUT OUT DIMENSIONS

Width:

560 mm

Depth:

480 mm

SUPPLY CONNECTIONS

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240 V 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

Spark Generator

Ispra Control's BF 50066
220- 240V  0.6 VA   T 120

Spark Gap

Fixed

Rear Left Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (auxiliary)

Heat Input

1.0 kW (3413 BTU/HR)

Rear Right Burner (semi rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner (rapid)

Heat Input

3.0 kW (10236 BTU/HR)

Central Burner (Ultra-rapid Triple-crown)

Heat Input

4.0 kW (13652 BTU/HR)

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Ultra-rapid

56

Aeration adjustment none

Instructions for the Installer

Engineers technical data

APPLIANCE CLASS

 : 3

APPLIANCE CATEGORY

: II2H3+

APPLIANCE GAS SUPPLY

: Natural gas G20 / 20mbar

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

MAX

MIN

 NOMINAL THERMAL
 POWER               kW

3.0

0.65

2.0

0.45

1.0

0.33

4.0

1.2

 NOMINAL FLOW
 RATE                  m

3

/h

0.286

0.062

0.190

0.043

0.095

0.031

0.381

0.114

 NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

146

Adjust.

 NOMINAL THERMAL
 POWER               kW

2.8

0.65

2.0

0.45

1.0

0.33

4.0

1.2

 NOMINAL FLOW
 RATE                  g/h

202

47

144

32

72

24

288

86

 NOZZLE REFERENCE

86

40

71

32

50

28

98

56

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

ULTRA-RAPID

(triple-crown)

Summary of Contents for ZGF 7820

Page 1: ...GAS HOB ZGF 7820 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB ...

Page 2: ...singtheappliancesafelywithout supervision or instruction by a responsible person to ensure that they can use the appliance safely During Use z This hob is intended for domestic cooking only It is not designed for commercial or industrial purposes z When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply k...

Page 3: ...you throughout the Instructions Safety Instructions Step by step instructions for an operation Hints and Tips Environmental Information Environmental Information z After installation please dispose of the packaging with due regard to safety and the environment z When disposing of an old appliance make it unusable by cutting off the cable z The symbol on the product or on its packaging indicates th...

Page 4: ...4 1 AuxiliaryBurner 2 Semi rapidBurners 3 Ultra rapid Triple crown Burner 4 RapidBurner 5 Controlknobs Description of the Hob 2 1 4 3 2 5 ...

Page 5: ... Avoid the use of the following household detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers Should the hob top become heavily soiled it is recommendedthatacleaningproductsuchasHobBrite or Bar Keepers Friend is used If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel ...

Page 6: ...antee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Cast Iron Pan Supports The hob has cast iron pan supports Take care when removing them They are very heavy and could damage the hob or your kitchen furniture if you let them fall down To keep the pan supports in th...

Page 7: ... kW 13652 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Ultra rapid 56 Aerationadjustmentnone Instructions for the Installer Engineers technical data APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3 APPLIANCE GAS SUPPLY Natural gas G20 20mbar BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 2 0 0 4...

Page 8: ...vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements For appliances installed in the Republic of Ireland please refer to the NSAI Domestic ...

Page 9: ...rew the parts together without using excessive force Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Ensure that the main connection p...

Page 10: ...in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections 1 FO 2563 2 Fitting the Hob into the worktop Carry out the building in of the hob as follows put the seals supplied with the hob on the edges of the cut out place them at 8 mm from the front and rear edges of...

Page 11: ...er E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there must be no cut or stray strands of wire present and the cable clamp must be secure over the outer sheath A c...

Page 12: ...fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of localburning arcingbutnofaultcouldbefoundunder test However a detailed visual inspection should reveal evidence of burning around the fault START Isolate appliance and carry out A Eart...

Page 13: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 14: ...and ignite another burner The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies Minimum adjustment screw Conversion from Natural Gas to LPG IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with natural gas but can be converted ...

Page 15: ...thin a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux Service and Spare Parts In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local Service Force Centre by telephoning 0870 5 929 929 Your telephone call will be automatically routed to the Ser...

Page 16: ...of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new country of residence for this particular model or range of appliances The appliance guarantee is personal to the original purchaser of the appliance and cannot be transferred to another user The appliance is installed and used in accordance with instructions issued by E...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...35687 8702 11 06 Grafiche MDM Forlì www zanussi electrolux co uk ...

Reviews: