8
Rear Left Burner
(semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Left Burner
(auxiliary)
Heat Input
1.0 kW (3412 BTU/HR)
Rear Right Burner
(semi rapid)
Heat Input
2.0 kW (6824 BTU/HR)
Front Right Burner
(rapid)
Heat Input
3.0 kW (10236 BTU/HR)
Instructions for the Installer
Engineers Technical Data
Overall dimensions
Width:
580 mm
Depth:
510 mm
Cut out dimensions
Width:
560 mm
Depth:
480 mm
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V ~ 50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
BURNER
RAPID
SEMI-RAPID
AUXILIARY
(large)
(medium)
(small)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE m
3
/h
0.286
0.062
0.190
0.043
0.095
0.031
NOZZLE REFERENCE
119
Adjust.
96
Adjust.
70
Adjust.
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
NOMINAL FLOW
RATE g/h
202
47
144
32
72
24
NOZZLE REFERENCE
86
40
71
32
50
28
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid
32
Rapid
40
Aeration adjustment none
NATURAL GAS
20 mbar
TYPE OF
GAS
Characteristics
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
APPLIANCE CLASS:
3
APPLIANCE CATEGORY:
II2H3+
APPLIANCE GAS SUPPLY:
Natural gas G20 / 20mbar
This appliance complies with the following
E.E.C. Directives:
* 73/23 - 90/683
(Low VoltageDirective);
* 93/68
(General Directives);
* 89/336
(Electromagnetical Compatibility Directive)
;
* 90/396
(Gas Appliances)
,
and subsequent modifications