19
Door reversing
Unplug the appliance before carrying out any
operation.
If necessary due to the place of installation or use, the
direction of door opening can be changed from right to
left. The appliances available on the market have right
opening. Carry out the following operations according to
the figures and explanations.
•
Place the appliance on its back
•
Remove the ventilation grille.
•
Unscrew the lower hinges.
•
Remove the door.
•
Unscrew the pin (f) and screw it on the opposite
side.
•
Unscrew the pin (d) and screw it on the opposite
side.
•
Refit the door.
•
Make sure the edge of the door is parallel with the
edge of the top.
•
Position and fix the bottom hinge on the opposite
side.
•
Remove the cap (e) and position it on the opposite
side.
•
Refit the ventilation grille.
•
Stand the appliance upright.
•
Fit the handle on the opposite side and put the
plastic caps (contained in the instructions bag) in
the free holes.
Put the appliance back in its place, level it and
wait at least two hours before connecting it.
If you do not wish to carry out the above operations,
please contact the nearest after-sales service.
Specialised technicians will carry out fitting at a
charge.
Important
After reversing the door, make sure the magnetic
seal adheres to the cabinet. If the room
temperature is cold (e.g. in winter), the seal may
not adhere perfectly to the cabinet. In that case,
wait until the seal has softened on its own or
speed up the process by warming the relevant part
with a normal hair-dryer.
PR220