• The indicator
continues to flash.
• The display shows the current setting: e.g.
= level 5.
2. Press
to change the setting. Each time you press the button, the level increases. After level 10 you
will start again from level 1.
3. Press the on/off button to confirm the setting.
If you use multi-tablets containing salt and the hardness of your water is lower than 21°dH,
you can set the lowest water softener level. It deactivates the salt refill indicator.
If you use standard detergent or multitablets without salt, set the proper water hardness level
to keep the salt refill indicator active.
THE WATER HARDNESS TABLE
German degrees
(°dH)
French degrees
(°fH)
mmol/l
Clarke degrees
Water softener
level
47 -50
84 - 90
8.4 - 9.0
58 - 63
10
43 - 46
76 - 83
7.6 - 8.3
53 - 57
9
37 - 42
65 - 75
6.5 - 7.5
46 - 52
8
29 - 36
51 - 64
5.1 - 6.4
36 - 45
7
23 - 28
40 - 50
4.0 - 5.0
28 - 35
6
19 - 22
33 - 39
3.3 - 3.9
23 - 27
5
1)
15 - 18
26 - 32
2.6 - 3.2
18 - 22
4
11 - 14
19 - 25
1.9 - 2.5
13 - 17
3
4 - 10
7 - 18
0.7 - 1.8
5 - 12
2
<4
<7
<0.7
< 5
1
2)
1) Factory setting
2) Do not use salt at this level.
DEACTIVATING THE RINSE AID EMPTY NOTIFICATION
While the appliance is in user mode:
1. Press
.
• The indicators
and
are off.
• The indicator
continues to flash.
• The display shows the current setting:
8