Problem and alarm code
Possible cause and solution
The programme does not start.
• Make sure that the appliance door is closed.
• Press Start.
• If the delay start is set, cancel the setting or wait for the end of
the countdown.
• The appliance recharges the resin inside the water softener.
The duration of the procedure is approximately 5 minutes.
The appliance does not fill with
water.
The display shows i10 or i11.
• Make sure that the water tap is open.
• Make sure that the pressure of the water supply is not too low.
For this information, contact your local water authority.
• Make sure that the water tap is not clogged.
• Make sure that the filter in the inlet hose is not clogged.
• Make sure that the inlet hose has no kinks or bends.
The appliance does not drain
the water.
The display shows i20.
• Make sure that the sink spigot is not clogged.
• Make sure that the interior filter system is not clogged.
• Make sure that the drain hose has no kinks or bends.
The anti-flood device is on.
The display shows i30.
• Close the water tap.
• Make sure that the appliance is correctly installed.
• Make sure the baskets are loaded as instructed in the user
manual.
The appliance stops and starts
more times during operation.
• It is normal. It provides optimal cleaning results and energy sav-
ings.
The programme lasts too long.
• If the delayed start option is set, cancel the delay setting or wait
for the end of the countdown.
The displayed programme du-
ration is different than the du-
ration in the consumption val-
ues table.
• Refer to the consumption values table in the chapter "Pro-
grammes".
The remaining time in the dis-
play increases and skips nearly
to the end of programme time.
• This is not a defect. The appliance is working correctly.
Small leak from the appliance
door.
• The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
• The appliance door is not centred on the tub. Adjust the rear
foot (if applicable).
The appliance door is difficult
to close.
• The appliance is not levelled. Loosen or tighten the adjustable
feet (if applicable).
• Parts of the tableware are protruding from the baskets.
The appliance door opens dur-
ing the wash cycle.
• The AirDry function is activated. You can deactivate the func-
tion. Refer to "Settings".
Rattling/knocking sounds from
inside the appliance.
• The tableware is not properly arranged in the baskets. Refer to
basket loading leaflet.
• Make sure that the spray arms can rotate freely.