background image

GAS HOB

ZDG 322

INSTRUCTION BOOKLET

Please read this instruction booklet before using the appliance

GB

Summary of Contents for ZDG322

Page 1: ...GAS HOB ZDG 322 INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance GB ...

Page 2: ...2 ...

Page 3: ...knobs are in the OFF position when not in use z When using other electrical appliances ensure the cable does not come into contact with the hot surfaces of the cooking appliance z Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage z Never leave the hob unattended when cooking with oil and fats z Never use plastic or aluminium foil...

Page 4: ...n of the Hob Important Safety Information 3 Description of the Hob 4 Operation 5 Maintenance and Cleaning 6 Something Not Working 7 Customer Care Department 8 Guarantee Conditions 9 Instructions for the Installer 10 Important safety requirements 11 Installation 12 Building In 13 Electrical connections 15 Wiring Diagram 16 Fault Finding 16 Commissioning 18 Conversion from Natural Gas to LPG 18 1 Ra...

Page 5: ...tallation or a power cut it is quite normal for the spark generator to be activated automatically To ensure maximum burner efficiency you should only use pots and pans with a flat bottom fitting the size of the burner used see table Burner minimum maximum diameter diameter Large rapid 180 mm 260 mm Small auxiliary 80 mm 160 mm If you use a saucepan which is smaller than the recommended size the fl...

Page 6: ...top become heavily soiled it is recommendedthatacleaningproductsuchasHobBrite or Bar Keepers Friend is used The Pan Supports The pan supports are dishwasher proof If the marks are particularly difficult to remove use common non abrasive cleaners or specific products Never use steel wool pads or acids The Burners Theburnercapsandcrownscanberemovedforcleaning Washtheburnercapsandcrownsusinghotsoapyw...

Page 7: ...rner cap and crown have been replaced correctly e g after cleaning Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning If after all these checks your hob still does not operate correctly contact your local Service Force Centre Please note that it will be necessary to provide proof of purcha...

Page 8: ...on on Zanussi products please contact our Customer Care Department by letter or tel ephone at the address below or visit our website at www zanussi co uk Customer Care Department Major Appliances Addington Way Luton Bedfordshire LU4 9QQ 08705 727727 calls to this number may be recorded for training purposes ...

Page 9: ...incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in use within a commercial or similar environment plus those which are the subject to rental agreements Products of Zanussi manufacture which are not marketed by Zanussi EuropeanGuarantee If you should move to another country within Europe then your gua...

Page 10: ... 28 Rapid 42 Aerationadjustmentnone Instructions for the Installer Engineers technical data APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3 APPLIANCE GAS SUPPLY Natural gas G20 20mbar BURNER RAPID AUXILIARY large small POSITION MAX MIN MAX MIN NOMINALTHERMAL POWER kW 3 0 0 65 1 0 0 33 NOMINALFLOW RATE m3 h 0 286 0 062 0 095 0 031 NOZZLEREFERENCE 119 Adjust 70 Adjust NOMINALTHERMAL POWER kW 2 8 0 65 1 0...

Page 11: ... a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before m...

Page 12: ...he washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carr...

Page 13: ...units or hoods must be placed at 650 mm minimum from the hob Carry out the building in of the hob as follows 1 Put the relevant sealings supplied with the hob on the edges of the cut out taking care that the sealings meet without overlapping 2 placethehobinthecutout takingcareofitscentring 3 fix the hob with the relevant screws Fig 3 The traction of the screws is able to trace the sealing any exce...

Page 14: ...istance intervention is needed Building over a kitchen unit with oven The hob recess dimensions must comply the indication given in Fig 2 and must be provided with brackets to allow a continuous supply of air To avoid overhating the building in should be carried out as shown in Figs 5 and 6 The hob s electric connection and the oven s one must be carried out separately both for safety reasons and ...

Page 15: ...he green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red Upon completion there must be no cut or st...

Page 16: ...found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of localburning arcingbutnofaultcouldbefoundunder test However a detailed visual inspection should reveal evidence of burning around the fault START Isolate appliance and c...

Page 17: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 18: ...nd ignite another burner The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar Turn off the burner supplies Minimum adjustment screw Conversion from Natural Gas to LPG IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with natural gas but can be converted...

Page 19: ...19 ...

Page 20: ...or kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world CUSTOMER CARE Major Appliances Addington Way Luton Bedfordshire LU4 9QQ Electrolux plc 2003 ...