Gas burners
BURNER
NORMAL POWER
kW
Natural Gas
INJECTOR MARK 1/100 mm
Btu/h
Auxiliary
1
70
3412
Semi-rapid
1.9
96
6483
Rapid
3
119
10236
Main Oven
1.7
95
5804
Gas Connection
Use a flexible pipe in compliance with the
regulation in force. Make sure they do not come
in touch with mobile parts and are not
squeezed.
WARNING!
Only a qualified and competent
person can do the gas installation.
Before you connect te gas,
disconnect the appliance from the
electricity supply or switch off the
fuse in the fuse box. Close the
primary valve of the gas supply.
Supply piping should not be less
than R3/8. Connection is made to
the Rc 1/2 (1/2 “ B.S.P.) female
threaded. The entry pipe is located
just below the hob level on the rear
left hand side of the appliance.
The gas supply ramp is on the rear
side of the appliance.
WARNING!
Only liquid sealants can be used
when the inlet gas pipe is fitted i.e.:
do not use the P.T.F.E. sealant tape.
When the installation is complete,
carry out a gas tightness test and
make sure that the seal of each pipe
fitting does not leak.
Use flexible tubing, which comply
with the BS.669 current edition.
B
C
C
D
E
A
WARNING!
The gas bayonet connector must be
in the marked area.
Dimension
mm
A
250
B
680
C
50
D
250
E
580
Pressure test
The Rapid injector is used as a pressure test
point.
1. Connect the pressure gauge to the Rapid
injector.
www.zanussi.com
21