39
The instructions given below are designed
specifically for a qualified installer and should aid
him or her to perform all installation, adjustment
and maintenance operations with absolute
precision and in compliance with all current
legislation and regulations. We strongly
recommend that all operations for the installationof
your cooker be carried out by Qualified Personnel
in accordance with existing rules and regulations.
Before the appliance is connected:
1) the protection fuse and the domestic wiring system
are suitable to carry the total electric load of the oven
(see rating plate);
2) your domestic wiring system has an efficient earth
connection in compliance with rules and laws in
force;
3) the wall socket or the omnipole switch used for the
electrical connection can easily be reached after the
oven is built in.
The appliance is supplied with connection cable fitted
with a standard plug suitable for the total electric load
shown on the rating plate.
The plug is to be inserted into a suitable wall socket.
In case of a direct connection to the mains, it is
necessary that you install a double pole switch between
the appliance and the electricity supply, with a minimum
gap of 3 mm. between the switch contacts and of a type
suitable for the required load in compliance with the
current rules. The yellow-green earth wire must not be
interrupted in any point and should be about 2 cm longer
than the neutral and phase wires.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50°C higher
than the room temperature.
After the connection is carried out, test the heating
elements for about 3 minutes.
Should the supply cord need to be replaced, use only
the following cable types: H07 RN-F, H05 RN-F, H05
RR-F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F.
Electrical Connection
Terminal block
The oven has an easily accessible terminal block, which
is meant to work with an electric single-phase rate of
220 V.
The manufacturer disclaims any responsability
should all the safety measures not be carried
out.