Problem
Possible cause
Solution
The compressor does not start
immediately after pressing the
QuickFreeze, or after changing
the temperature.
This is normal, no error has oc-
curred.
The compressor starts after a peri-
od of time.
Water flows on the floor.
The melting water outlet is not
connected to the evaporative
tray above the compressor.
Attach the melting water outlet to
the evaporative tray.
Temperature cannot be set.
The QuickFreeze or QuickChill
function is switched on.
Switch off QuickFreeze or Quick-
Chill manually, or wait until the
function resets automatically to set
the temperature. Refer to "Quick-
Freeze or QuickChill function".
DEMO appears on the display.
The appliance is in demonstra-
tion mode.
Keep the Mode pressed for approx-
imately 10 seconds until a long
sound is heard and display shuts
off for a short time.
The temperature in the appliance
is too low/too high.
The temperature regulator is
not set correctly.
Set a higher/lower temperature.
The food products' tempera-
ture is too high.
Let the food products temperature
decrease to room temperature be-
fore storage.
The door has been opened of-
ten.
Open the door only if necessary.
The QuickFreeze function is
switched on.
Refer to "QuickFreeze function".
There is no cold air circulation
in the appliance.
Make sure that there is cold air cir-
culation in the appliance.
If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to
"Installation".
3. If necessary, replace the defective door
gaskets. Contact the Authorised Service
Centre.
Installation
Positioning
This appliance can be installed in a dry, well
ventilated indoor where the ambient
temperature corresponds to the climate class
indicated on the rating plate of the appliance:
Climate
class
Ambient temperature
SN
+10°C to + 32°C
www.zanussi.com
23