7
Water contains, a
variable quantity of
limestone and
mineral salts of
which quantities
vary according to
geographical
locations thus
varying its
conductivity values.
Relevant variations
of the conductivity
of the water
compared to those
prefixed by the
factory could slightly
influence the
residual humidity of
the laundry at the
end of the cycle.
Your dryer allows
you to regulate the
sensitivity of the
drying sensor based
on conductivity
values of the water
by using the
following procedure.
Procedure:
Turn the
programme selector
dial to switch on the
appliance In
selection mode
press
simultaneously the
buttons
3
and
6
until
«C0»
appears on the
digits.
Adjusting the
level of
conductivity:
Press the button
6
sequentially: the
level of conductivity
is indicated by the
lighting of the
horizontal hyphens.
Normally, the
appliance is
factory-set to the
highest level;
however, certain
models may be
configured
differently.
Memorizing the
new setting:
Simultaneously
press down the
buttons
3
and
6
until
the previous drying
cycle time appears
again on the display
and the buzzer
sounds.
Adjusting the level of conductivity
1 2 3 4 5
6
Display
Conductivity degree
Approximative value
(µS/cm)
CO
Low
< 300
CO
Medium
300 - 600
CO
High
> 600
5
6
1 2 3 4