6
Adjusting the level of conductivity
Water contains, a variable quantity of limestone and
mineral salts of which quantities vary according to
geographical locations thus varying its conductivity
values.
Relevant variations of the conductivity of the water
compared to those prefixed by the factory could
slightly influence the residual humidity of the laundry
at the end of the cycle.
Your dryer allows you to regulate the sensitivity of
the drying sensor based on conductivity values of
the water by using the following procedure.
To access adjustment mode:
Turn the programme selector dial to switch on the
appliance. In selection mode, press simultaneously
the buttons
2
and
4
.
Press the buttons down until the pilot lights above
each ones begin to flash and one of the pilot lights
indicating the drying phase lights
Drying
, cooling
COOLING
, or end cycle
ENDE
remains lit.
1 2 3 4 5
3h
6h
9h
DELAY
START
QUICK
START/
PAUSE
LOW
TEMP
.
NO
BU
ZZ
ER
CLOGGED
CONDENSER
DRYING
COOLING
END
CLOGGED
F
ILTERS
F
ULL
TANK
COTTON
SYNTHETIC
TIMED
PROGRAMME
EXTRA
DRY
READY
TO
WEAR
STORE
DRY
SLIGHTLY
DAMP
IRON
DRY
WRING
DRY
EXTRA
DRY
STORE
DRY
IRON
DRY
BABY
DRY
90'
60'
30'
DRY
F
RESH
COOLING
TCE
7145
Adjusting the level of conductivity:
Press the START/PAUSE
button sequentially:
the level of conductivity is indicated by the phase
pilot lights, which light in various combinations as
follows:
Normally, the appliance is factory-set to the highest
level; however, certain models may be configured
differently.
Memorizing the new setting:
Simultaneously press the buttons
2
and
4
.
Press the buttons down until the pilot lights above
each ones stop flashing and the buzzer sounds.
LED lit
Conductivity
Approximate value
µS/cm
ENDE
Low
< 300
COOLING
Medium
300 - 600
Drying
High
> 600
125993762.qxp 2004-08-27 12:51 Page 6