background image

HALF MODULE GAS FRY TOPS-THERMOSTATIC

N 900

BACI1

2009-09-29

The Company reserves the right to alter technical specifications without prior notice.

www.zanussiprofessional.com

ZANUSSI

P R O F E S S I O N A L

WATER DRAIN FOR FRY TOP HALF MODULE

206153

206153

206153

WATER COLUMN WITH SWIVEL ARM

206288

206288

206288

WATER COLUMN EXTENSION FOR 900 LINE

206290

206290

206290

STOPPER FOR FRYTOPS

206296

STAND/SUPPORT 400 MM

206183

206183

206183

SIDE HANDRAIL-RIGHT/LEFT HAND

206165

206165

206165

SCRAPER FOR SMOOTH PLATE FRY TOP

164255

164255

SCRAPER FOR RIBBED PLATE FRY TOP

164257

REAR FLUE UPSTAND FOR SMALL CHIMNEY

206159

206159

206159

PRESSURE REGULATOR FOR GAS UNITS

927225

927225

927225

PAIR OF COVERING STRIPS FOR END ELEMENTS

206234

206234

206234

LARGE HANDRAIL(PORTIONING SHELF)800 MM

206186

206186

206186

LARGE HANDRAIL(PORTIONING SHELF)400 MM

206185

206185

206185

JUNCTION SEALING KIT

206086

206086

206086

FRONTAL HANDRAIL 800 MM

206167

206167

206167

FRONTAL HANDRAIL 400 MM

206166

206166

206166

FRONTAL HANDRAIL 1600 MM

206192

206192

206192

FRONTAL HANDRAIL 1200 MM

206191

206191

206191

FLUE CONDENSER  FOR 1/2 MOD. DIAM.120MM

206155

206155

206155

DRAUGHT DIVERTER WITH 120 MM DIAMETER

206126

206126

206126

CHIMNEY UPSTAND 400MM 

206303

206303

2 SIDE COVERING PANELS FOR TOP-D=900MM

206278

206278

206278

NRG4HMS

200203

NRG4SMR

200205

NRG4SCS

200207

ACCESSORIES

MODELS

OPTIONAL ACCESSORIES

 Models with horizontal plate are ideal for 

damp cooking.  

 The chrome plate ensures that energy is 

transferred directly into the food and not 
towards the operator.

 Main connections can be via the base or 

the rear of the unit.

 All gas appliances are supplied for use 

with natural gas, with LPG conversion jets 
supplied as standard.

 Very quick heat-up time to maximum 

temperature.

 The special design of the control knob 

system guarantees against water infiltration.

 All top models can be easily mounted on 

refrigerated base, open base cupboards, 
bridging supports or cantilever systems.

 Removable splashback in stainless steel 

and scrapers with smooth/ribbed blades 
included as standard, allowing an easier and 
faster cleaning process.

 IPX5 water protection.

  

* In accordance with 

H

 regulations for gas models 

belonging to Class B11 (power over 14 kW), it is 
necessary to install a chimney (if installed under a 
hood) or chimney and draft diverter if the waste gases 
are vented directly outside. 

  
Productivity/h (full module, chromium)

 210 Hamburger fresh 100gr

 240 Pilard of veal 80 gr

 336 Sliced oubergine 1 cm

 168 Sausages 100 gr cut lengthways

 300 Sliced zucchini 1/2 cm

 112 Pork ribs 160 gr

 240 Sliced turkey 100 gr

 108 Sliced salmon 200 gr

Productivity/h (full module, mild steel)

 252 Hamburger fresh 100 gr

 360 Pilard of veal 80 gr

 384 Sliced oubergine 1 cm

 168 Sausages 100 gr cut lengthways

 300 Sliced zucchini 1/2 cm

 112 Pork ribs 160 gr

 240 Sliced turkey 100 gr

 108 Sliced salmon 200 gr

 

Reviews: