28
TECHNICAL DETAILS
DIMENSIONS
Height:
900
mm
(nominal)
Width:
550
mm
(nominal)
Depth:
600 mm (to front of door panel)
Weight:
61.8
Kg Net
Space for fixing at hotplate level 2mm minimum clearance
Space for fixing above hotplate level. See important note 'Location of Appliance'.
Minimum space above hotplate 750mm (If cooker hood is fitted refer to the cooker hood installation instructions.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel)
CONNECTIONS
Gas connection: -
Rear left hand side of appliance at hotplate level
Rc ½ (½” B.S.P. female)
Electrical connection: -
230 - 240 V 50 Hz Mains connected at rear centre of appliance using at
least 6mm
2
multi core PVC insulated cable.
HOTPLATE
Natural Gas
Heat
Input
R.H.F
R.H.R
L.H.R
L.H.F
1.0kW
1.9kW 1.9kW
2.9kW
(3412 Btu/h)
(6483 Btu/h)
(6483 Btu/h)
(9895 Btu/h)
Injector
Marking
070
096
096
119
L.P.Gas
Heat
Input
1.0kW
1.9kW
1.9kW
2.8kW
(71.8g/h)
(136.5g/h)
(136.5g/h)
(194.0g/h)
Injector
Marking
050
071
071
086
GRILL
Natural Gas
L.P.Gas
Heat
Input
2.7kW
(9215
Btu/h)
2.45kW (176g/h)
Injector Marking
121
078
MAIN
OVEN
Heat
Input
2.4kW
(8189
Btu/h)
2.4kW (172.4g/h)
Injector Marking
108
078
Thermostat
By-Pass
Marking
69
78
GENERAL
Ignition
(H.T.
Spark)
Spark
Gap
3-4mm
GAS CATEGORY COUNTRIES OF DESTINATION
CAT. I
2H
GB
CAT. I
3+
GB
This appliance complies with: European Council Directives Low voltage Directive
73/23/EEC ,Gas Directive 90/396/EEC EMC Directive 89/336/EEC, CE Marking
Directive 93/68/EEC.