42
ALU
High temperature alarm setting
10
ALL
Low temperature alarm setting
5
AHy
Differential for temperature alarm
2
ALd
Temperature alarm delay
15
dLU
High temperature alarm setting (defrost probe)
150
dLL
Low temperature alarm setting (defrost probe)
-55
dAH
Differential for temperature alarm (defrost probe)
1
ddA
Temperature alarm delay (defrost probe)
15
FLU
High temperature alarm setting (fan probe)
150
FLL
Low temperature alarm setting (fan probe)
-55
FAH
Differential for temperature alarm (fan probe)
1
FAd
Temperature alarm delay (fan probe)
15
dAo
Delay of temperature alarm at start-up
04:00
EdA
Alarm delay at the end of defrost
60
dot
Temperature alarm exclusion after door open
60
Sti
Stop regulation interval
nu
Std
Stop duration
3
oA1
First relay output configuration
CPr
oA2
Second relay output configuration
dEF
oA3
Third relay output configuration
FAn
oA4
Fourth relay output configuration
LiG
oA5
Fifth relay output configuration
ALr
oA6
Sixth relay output configuration
PrP
CoM
Modulating output configuration
CUr
AOP
Alarm relay polarity
CL
iAU
Auxiliary output indipendent from ON/OFF state
no
i1P
Digital input 1 polarity
OP
i1F
Digital input 1 configuration
bAL
d1d
Digital input 1 activation delay
0
i2P
Digital input 2 polarity
OP
i2F
Digital input 2 configuration
PAL
d2d
Digital input 2 activation delay
10
i3P
Digital input 3 polarity
CL
i3F
Digital input 3 configuration
dor
d3d
Digital input 3 activation delay
15
nPS
Number of pressure switch activation before lock
3
OdC
Compressor and fan status when open door
F-C
rrd
Outputs restart after door open alarm
30
_HES
Temperature increasing during Energy Saving
ESP
Energy saving probe selection
P1
HES
Temperature increasing during Energy Saving
0
PEL
Energy saving activation when Light switched off
nu
LMd
Defrost Synchronisation
YES
dEM
Defrost end Synchronisation
YES
LSP
SET-POINT Synchronisation
YES
LdS
Display Synchronisation (temperature sent via LAN)
no
LOF
ON/OFF Synchronisation
YES
LLi
Light Synchronisation
YES
LAU
AUX Synchronisation
no
LES
Energy Saving Synchronisation
YES
LSd
Remote probe displaying
no
LCP
P4 value sent in LAN
no
StM
Cooling request from LAN enable compressor relay
no
ACE
Cold Calling in LAN always enabled (even if the compressor block)
YES
P1C
P1 configuration
ntC
ot
P1 calibration
0