_______________________________________________________________4. INSTALLATION
____________________________________________________________________________
14
CITIZEN 6 - 9/MC, CITIZEN 6+6 - 9+9/MC ELECTROMECHANICAL VERSION
dispersion capacity as the appliance itself. The efficiency of this system
must be correctly verified according to the norms in force.
The power cable must terminate with a plug to connect to the electrical
switchgear having a corresponding differential magneto thermal switch.
The equipment is not supplied with a power plug.
The coupling between plug and socket must be such that the earth
conductor is connected first and disconnected last and must have the right
dimensions for the rated current (see Table 3-1). Plugs and sockets for
industrial use of the type CEE17 are suitable or those which satisfy European
norm EN 60309.
The thermal circuit breaker must be calibrated to the total rated current and
the magnetic circuit breaker calibrated to the rated current (In the case of
ovens this is only slightly higher than rated current), while the differential
mechanism must be calibrated to the 30 mA current (see Table 3-1).
The electrical socket must be easily accessible and must not require further
location after the installation of the equipment. The distance between the
equipment and the socket must be sufficient to avoid stretching the power
cable
The power cable must never be trapped under the feet or
wheels of the equipment
If the Power cable is damaged it must be substituted by
customer support or by a qualified service engineer so as to avoid
any risk.
The manufacturer does not accept responsibility for damage caused
by failure to observe the abovementioned norms.
For the position of the electrical power connections, see Fig. 4.3.
4.6 Emissions from cooking appliance
ATTENTION!
Proceed with the installation of the oven according
to the norms defined by current legislation in the country concerning
the installation of this typology of oven so as to guarantee the
sustainability of a healthy working environment. For more information it
is recommended that specific norms be consulted.