ZANKER MET 60 Operation And Installation Instructions Manual Download Page 4

4

1.1  Description of the unit 

This manual must be read carefully before attempting to install 
the mini multipoint water heater.  If you do not follow the 
safety rules or the instructions outlined in this manual, the unit 
may not operate properly and it could cause property damage, 
serious body injury and/or death.

ZANKER will not be liable for any damages because of failure to 
comply with the installation and operating instructions outlined in 
this manual or because of improper use.  Improper use includes 
the use of this appliance to heat any liquid other than water.  
Failure to comply with the installation and operating instruc-
tions or improper use voids warranty.  Never remove the unit’s 
plastic cover unless the electricity is turned off.

If you have any quesions regarding the installation or operation 
of this water heater, or if you need an additional installation 
manual, please call our technical service line and we will refer 
you to a qualified ZANKER service representative in your area.

General
The Mini Multipoint water heater does not store hot water. 
Instead, water is heated instantaneously as it flows through 
the unit.
The input of heat into the water is electronically controlled. 
Please set the desired temperature using the knob on the front 
cover. The LED lights up when the unit is “ON”.

1.2  Detail description (Fig 6)

 

1.  Fixing hole (2 nos.)

 

2  Cable seal

 

3.  Step switch

 

4.  Differential pressure switch assembly

 

5.  Cold water connection

 

9.  Hot water connection

 

7.  Water container assembly

 

8.  Thermostat

 

  9.  Filter

        10.  Union nut (provided by client)

1.3 Installation instruction 

for the qualitified installer

  

1.  Install the Mini Multipoint as close as possible to the    

 

  main hot water draw-off points.

 

2.  Leave a minimum of 5” of clearance on all sides for    

 

  servicing.

 

3.  Remove plastic cover. (Fig 3)

 

4.  Mount unit securely to wall by putting two screws  

 

 

  through mounting holes. Screws and plastic  wall plugs  

 

  for mounting are provided. (Fig 4)

 

Water connections

 

1.  All plumbing work must comply with national and 

 

  applicable state and local plumbing codes.

 

2.  Make certain that the cold water supply line has been   

 

  flushed to remove any scale and dirt.

 

3.  Cold water connection (inlet) is on the right side of the  

 

  unit (Fig 6 # 5), hot water connection (outlet) is on the  

 

  left side of the unit. (Fig 6 # 6)

 

5.  When all plumbing work is completed, check for leaks    

 

  and take corrective action before proceeding.

 

Unit must be installed in a vertical position with the    

 

water fittings pointing downward.  Do not install unit 

where it would routinely be splashed with water.  Electric 
shock may result. 

1.4 Electrical connection

 

1.  All electrical work must comply with national and ap   

 

  plicable state and local electrical codes.

 

2.  The Mini Multipoint should be connected to a properly  

 

  grounded dedicated branch circuit of proper voltage   

 

  rating.  In installation with several Mini Multipoint units,  

 

  each unit requires an independent circuit. 

 

3.  The “live” wires must be connected to the slots on the   

 

  terminal block marked L.   The ground wire must 

 

  be connected to the slot marked with the ground  

 

 

  symbol.

 

4.  Reinstall plastic cover.

 

Warning:

 

Before begining any work on the electric installation, 

be sure that main breaker panel switch is, “OFF” to avoid any 
danger of electric shock.  All mounting and plumbing must be 
completed before proceeding with electrical hook-up where 
required by local, state or national electrical codes the circuit 
should be equipped with a “Ground fault interrupter”.

1.5  Regulations and Provisions

-  Regulations of the local power supply company should be    
   observed.
-  Regulations of the water supply company should observed
-  Technical data.
-  Install the unit flush with the wall.
-  Electrical connection to be secure.
-  The device must be capable of being isolated from the mains, 
   for example by fuses, with an isolating distance of at least 
   3 mm, in all poles.

 

The unit must be earthed (see circuitdiagram). To protect  

 

against water penetration, the cable seal (3) must be used.

1.6 Important note

 

All the information in these Operating and Installation  

 

Instructions must be carefully followed. These instructions 

provide important details regarding the safety, operation, 
installation, and maintenance of the unit.

1.7 Installation location

 

The  unit is to be installed in a closed, frost-free room 

 

(disconnected units are to be  stored in a frost-free 

location, since there will always be some water left in the unit) 
The MET 60  is to be installed vertically on a wall (hot water 
connection downwards).