12
Installation
10.3 Connecting the power supply
DANGER Electrocution
Carry out all electrical connection and installation
work in accordance with regulations.
DANGER Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the
power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
DANGER Electrocution
The appliances are delivered with a power cable
(MDO 35 with plug).
Connection to a permanent power supply is pos-
sible, provided the fixed cable has a cross-section
that is at least equal to that of the standard power
cable of the appliance. A maximum cross-section of
3 x 6 mm² may be used.
»
If the appliance is installed over the sink, route
the power cable behind the appliance.
!
Material losses
When making the connection to a standard safety
socket (in the case of a power cable with plug), en-
sure that the socket is freely accessible after the
appliance has been installed.
!
Material losses
Take note of the type plate.
The specified voltage
must match the mains voltage.
» Connect the power cable as shown in the wiring dia-
gram (see chapter „Specification / Wiring diagram“).
11. Commissioning
11.1 Initial start-up
26
_0
2_0
5_00
87
» Fill the appliance by running the tap several times
until the pipework and appliance are free of air.
» Carry out a tightness check.
» Insert the power cable plug, if present, into the stan-
dard safety socket or set the fuse/MCB.
» Check the function of the appliance.
» In the case of oversink installation, affix the company
logo supplied over the existing company logo.
11.2 Appliance handover
» Explain the appliance function to users and familiari-
se them with its operation.
» Make users aware of potential dangers, especially
the risk of scalding.
» Hand over these instructions.