©Zanda Pty Ltd – Futura Integrated Privacy Door Furniture Fitting Instructions - Page 2 of 2 (Up-dated Feb 2013)
DUMMY FIXING MOUNT – FUTURA ELITE DOOR FURNITURE
Code 1152 – 8mm Spindle
Zanda 1152 8mm dummy fix mounts are designed to be recessed and screwed onto the door face, with the handle slipping over the top. The
handle base plate is then screwed to or bolted through the door.
Note:
It is important to ensure solid fixing is available for handle and dummy mount screws (especially on hollow core doors).
Fitting Instructions:
1.
Test dummy spindle on handle to ensure it fits.
2.
Establish height and position for handle on door.
3.
Drill a 32mm diameter recess on the face of door to a depth of 4mm.
4.
Fit the dummy spindle by drilling and fitting the three wood screws.
Note: Grooved side of spindle must be aligned with grub screws on levers.
5.
Install the handle onto the spindle ensuring that it sits squarely on the doors face.
6.
Attach the handle by screwing the base plate to the door. In some cases where through door bolts are provided, the door can be
drilled both sides to accept the through screws.
7.
Press on conceal fix rose to base plate and tighten grubscrew on underside.
8.
Tighten the grubscrew onto dummy spindle.
Note: The grub screw may need a re-tighten after bedding-in period. We Recommend Medium Strength Thread-lock to be used,
Windsor Code: 1276.
Note: No warranty on Futura levers when used as dummies if 1152 Taylor Spindle is not fitted.
Back to Back Dummy Fixing Mount:
Code 1152 – 8 mm Spindle
Refer to instructions over page when fitting Dummy Levers back to back (using thru-fixing screws).