Zamel ROP-03 Manual Download Page 4

RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1

RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2

BISTABLE mode:

SWITCH ON/SWITCH OFF mode (two push-buttons):

TIME mode (one push-button):

An exemplary programming procedure with the use of P-257/2 remote control. The 

procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: Every 

transmitter can cooperate with ROP-03 in a different mode, depending on how they 

were added to the device. One transmitter can be added during one programming 

cycle. Full memory is signalled with pulsating LED red diode.

Press the transmitter’s 

push-button for a longer 

time. LED red diode 

switches on (first signal 

pulsates, next the signal is 

constant)

Press and release 

transmitter’s push-button. 

LED red diode switches on 

(first the signal pulsates, 

next the signal is constant)

Press and release the first 

transmitter’s push-button. 

LED red diode switches on 

(first the signal pulsates, 

next the signal is constant)

Press and release the same 

transmitter’s push-button. 

LED red diode switches on 

(the signal pulsates) and 

next it switches off - THE 

TRANSMITTER IS ADDED

Press and release the same 

transmitter’s push-button. 

LED red diode switches on 

(the signal pulsates) and 

next it switches off - THE 

TRANSMITTER IS ADDED

Press and release the 

second transmitter’s 

push-button. LED red 

diode switches on (the 

signal pulsates) and 

next it switches off - THE 

TRANSMITTER IS ADDED

Press PROG push-button of 

ROP-03 device for a longer time 

until LED red diode switches on 

(constant signal). Next release 

PROG push-button.

Press PROG push-button of 

ROP-03 device for a longer time 

until LED red diode switches on 

(constant signal). Next release 

PROG push-button

Press PROG push-button of 

ROP-03 device for a longer time 

until LED red diode switches on 

(constant signal). Next release 

PROG push-button

Press the 

transmitter’s 

push-button 

for a longer 

time.

Release the 

transmitter’s 

push-button. LED 

red diode switches 

on (first the signal 

pulsates, next the 

signal is constant).

Press the same transmit-

ter’s push-button and 

release it. LED red 

diode switches on (the 

signal pulsates) and 

next it switches off - THE 

TRANSMITTER IS ADDED.

Press PROG push-button 

of ROP-03 device for a 

longer time until LED 

red diode switches on 

(constant signal). Next 

release PROG push-

button

MONOSTABLE mode:

CAUTION:

For the monostable mode press the remote control push-button before pressing 

PROG push-button.

Press PROG push-button of ROP-03 device for a longer 

time until LED red diode switches on (constant signal). 

Next release PROG push-button. Wait (about 5 seconds) 

until LED red diode switches on (first the signal pulsates, 

next the signal is constant).

Choose one mode out of five 

ROP-03 operation modes and 

programme the device similarly 

as for channel 1.

OPERATION TABLE

Symb

ol

RNK

-02

RNK

-04

P-256/8

P-257/2

P-257/4

RNM

-10

RNP

-01

RNP

-02

RNL

-01

RTN-01

RCR-01

RTI-01

RXM

-01

P-260

ROP

-03

200 200 250 200 200  250 180 180 180 200 180 180 250

-

CAUTION: The given range concerns open area - an ideal condition without any natural 

or artificial obstacles. If there are some obstacles between a transmitter and a receiver, 

it is advisable to decrease the range according to: bricks: from 10 to 40 %, wood and 

plaster: from 5 to 20 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, 

glass: from 10 to 20 %. Over- and underground medium and high electrical power 

lines, radio and television transmitters, GSM transmitters set close to a device system 

have also a negative influence on the range. 

Summary of Contents for ROP-03

Page 1: ...on the monostable mode the bistable and time modes The receiver is recommended for use with LED diode lighting Characteristic features cooperation with wireless EXTA FREE system transmitters independent control of up to two receivers in the following modes switch on switch off monostable bistable time 2 relay potential free outputs NO with a maximum capacity of 5 A for 250V AC wide operation range...

Page 2: ...on box The product belongs to the ECOLINE group and is characterised by low power consumption The features of the controller cooperation with wireless EXTA FREE system transmitters realisation of the control function in low voltage installations including LED diode lighting two output relays dry contacts the possibility of independent control of two circuits multiplicity of operation modes switch ...

Page 3: ... switches on first signal pulsates next the signal is constant Wait for the third time about 5 seconds until LED red diode switches on first signal pulsates next the signal is constant After the adjusted time is finished the number of LED red diode flashes press PROG push button and then release it TIME IS ADDED After the adjusted time is finished the number of LED red diode flashes press PROG pus...

Page 4: ...t signal Next release PROG push button Press PROG push button of ROP 03 device for a longer time until LED red diode switches on constant signal Next release PROG push button Press the transmitter s push button for a longer time Release the transmitter s push button LED red diode switches on first the signal pulsates next the signal is constant Press the same transmit ter s push button and release...