![Zamel ROP-03 Manual Download Page 4](http://html1.mh-extra.com/html/zamel/rop-03/rop-03_manual_3143115004.webp)
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 1
RADIO TRANSMITTERS PROGRAMMING - CHANNEL 2
BISTABLE mode:
SWITCH ON/SWITCH OFF mode (two push-buttons):
TIME mode (one push-button):
An exemplary programming procedure with the use of P-257/2 remote control. The
procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: Every
transmitter can cooperate with ROP-03 in a different mode, depending on how they
were added to the device. One transmitter can be added during one programming
cycle. Full memory is signalled with pulsating LED red diode.
Press the transmitter’s
push-button for a longer
time. LED red diode
switches on (first signal
pulsates, next the signal is
constant)
Press and release
transmitter’s push-button.
LED red diode switches on
(first the signal pulsates,
next the signal is constant)
Press and release the first
transmitter’s push-button.
LED red diode switches on
(first the signal pulsates,
next the signal is constant)
Press and release the same
transmitter’s push-button.
LED red diode switches on
(the signal pulsates) and
next it switches off - THE
TRANSMITTER IS ADDED
Press and release the same
transmitter’s push-button.
LED red diode switches on
(the signal pulsates) and
next it switches off - THE
TRANSMITTER IS ADDED
Press and release the
second transmitter’s
push-button. LED red
diode switches on (the
signal pulsates) and
next it switches off - THE
TRANSMITTER IS ADDED
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button.
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button
Press PROG push-button of
ROP-03 device for a longer time
until LED red diode switches on
(constant signal). Next release
PROG push-button
Press the
transmitter’s
push-button
for a longer
time.
Release the
transmitter’s
push-button. LED
red diode switches
on (first the signal
pulsates, next the
signal is constant).
Press the same transmit-
ter’s push-button and
release it. LED red
diode switches on (the
signal pulsates) and
next it switches off - THE
TRANSMITTER IS ADDED.
Press PROG push-button
of ROP-03 device for a
longer time until LED
red diode switches on
(constant signal). Next
release PROG push-
button
MONOSTABLE mode:
CAUTION:
For the monostable mode press the remote control push-button before pressing
PROG push-button.
Press PROG push-button of ROP-03 device for a longer
time until LED red diode switches on (constant signal).
Next release PROG push-button. Wait (about 5 seconds)
until LED red diode switches on (first the signal pulsates,
next the signal is constant).
Choose one mode out of five
ROP-03 operation modes and
programme the device similarly
as for channel 1.
OPERATION TABLE
Symb
ol
RNK
-02
RNK
-04
P-256/8
P-257/2
P-257/4
RNM
-10
RNP
-01
RNP
-02
RNL
-01
RTN-01
RCR-01
RTI-01
RXM
-01
P-260
ROP
-03
200 200 250 200 200 250 180 180 180 200 180 180 250
-
CAUTION: The given range concerns open area - an ideal condition without any natural
or artificial obstacles. If there are some obstacles between a transmitter and a receiver,
it is advisable to decrease the range according to: bricks: from 10 to 40 %, wood and
plaster: from 5 to 20 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%,
glass: from 10 to 20 %. Over- and underground medium and high electrical power
lines, radio and television transmitters, GSM transmitters set close to a device system
have also a negative influence on the range.