TECHNICAL DATA

• power supply: 1x battery 9 V 

type: 6F22

• detector: photoelectric
• power input in sleep mode: 

12 µA

• power input during the alarm: 

20 mA

• sound volume: 85 dB
• optical signalling: LED
• compliant with the standard: 

EN14604:2005/AC1:2008

• protection class: III
• protection rating: IP20
• temperature operating range: 

from -10°C to +40°C

• humidity operating range:  

up to 90% RH

• dimensions [mm]: ø 103x32

1

2

INSTALLATION

• The smoke sensors should be installed in the middle  

of the ceiling of the rooms that are to be monitored for fire.

• The optimal solution ensuring the maximum protection  

is to place one detector in every room (excluding bathroom, 

boiler room, etc.)

• At the minimum you should place at least one detector  

on each floor of the building.

• You must make sure that the alarm signal can be well heard 

from other rooms.

• The detector should not be installed near windows, ventilation 

grilles or air-conditioners that may affect the measurement, 

nor in bathrooms where the steam may trigger a false alarm.

• The detector should not be installed in rooms with high level 

of dust (e.g. boiler rooms) and in rooms that do not meet the 

requirements as for the acceptable levels of temperature  

and/or humidity (e.g. bathrooms).

In order to install the device:

• disassemble the backside 

of the casing by twisting  

it counterclockwise in order 

to release the clips

• plug the battery (9 V type 

6722) into the clip and put 

it in by pressing the red 

lock (1), which is to prevent 

closing the detector without 

installing the battery first (2)

• screw the backside of the 

casing to the wall with the 

screws included in the 

package, and then place 

the detector on the wall by 

rotating it clockwise until the 

clips click into place

„test/hush” button

signal LED

FUNCTIONS

1. First boot-up

After mounting the battery you must press and hold the button, 

TEST/HUSH, until a sound signal is made and a red LED goes 

on. It is a technical condition test that means that the device works 

properly. It recommended to do such tests once per month, which 

also will result in regular checks of the device’s technical condition.

2. Normal operation mode

After doing the test by pressing and holding the TEST/HUSH button 

the device will go into a lowered sensitivity mode, signalled by  

the diode blinking once per 10 seconds. Approximately after  

10 minutes the detector will go into the normal operation and threat 

detection mode, signalled by the red diode blinking once per  

43 seconds.

3. Alarm

If the device detects smoke in the room, a loud sound signal  

is made and the diode starts blinking.

4. Alarm mute function

If the smoke has been detected and the alarm has gone off, the 

user can mute the alarm by pressing the “TEST/HUSH” button. 

In that case only the diode keeps on blinking every 10 seconds 

and the device goes into the lowered sensitivity mode. After 

approximately 10 minutes the device goes back to the normal 

operation and threat detection mode. If the threat is not gone,  

the loud alarm will go off again.

5. Low battery signalling.

If the battery is low, the detector indicates it with a single sound 

signal made every 43 seconds. It means that the battery in the 

device must be replaced immediately.

NOTE

• clean the device regularly,  

do not let any dust into the 

air-intake of the detector

• install the devices in places 

that meet the requirements 

as for the acceptable 

temperature and humidity

• do not cover the device in 

paint when painting the walls

• do not spray cleaning 

products directly to the device

• do not let any water-spills  

on the detector

• install the detectors  

n accordance with the 

recommendations (section: 

Installation)

• test the device once per 

month or every time the 

battery is replaced

It must be noted that smoke 

detectors improve safety, 

yet do not guarantee a 100% 

certainty of the detection  

of fire due to the possibility 

of a breakdown, discharged 

battery or an impact of 

external factors on the 

detector. Thus, it is crucial 

to systematically test the 

technical condition of the 

detectors (as indicated in 

this manual) and replace 

the batteries immediately, 

whenever the need of its 

replacement is indicated  

by the detector.

PLEASE READ THIS 

MANUAL THOROUGHLY 

BEFORE INSTALLING  

THE DETECTOR.