DESCRIPTION
LOCAL CONTROL – DOUBLE ROLLER BLIND PUSH-BUTTON
n this mode, the SRM-11 controller realizes the following functions after pressing shortly (<0,5 sec.) the appropriate push-buttons: opening,
closing or stopping the roller blind equipped with 230 V AC single-phase motor. Roller blind movement is consistent with time programmed
in a controller. The default time is 120 seconds. Pressing the local control push-button for the first time, causes the roller blind moves in a
selected direction, however the subsequent pressing of a push-button stops the roller blind. Its movement is signalled optically by a flashing
LED. Pressing longer (>2,5 sec.) the suitable local control push-button causes the activation of programmed comfort settings (up / down).
Activation of the upper comfort setting:
In order to activate the upper comfort setting, open completely the roller blind. Next, press longer (>2,5 sec.) the local (L ) control push-but-
ton. The roller blind starts closing and it will automatically stop in the adjusted upper comfort position.
Activation of the lower comfort setting:
In order to activate the lower comfort setting, close completely the roller blind. Next, press longer (>2,5 sec.) the local (L ) control push-but-
ton. The roller blind starts opening and it will automatically stop in the adjusted low comfort position.
LOCAL CONTROL – SINGLE PUSH-BUTTON
Local control by means of a single push-button is possible after input connection: L ( ) and L ( ).
In this mode, after pressing shortly (<0,5 sec.) the local control push-button, the SRM-11 controller realizes the following functions: opening,
closing or stopping the roller blind equipped with 230 V AC single-phase motor. Roller blind movement is consistent with time programmed
in a controller. The default time is 120 seconds. The roller blind movement operates according to a sequence: open – stop - close. Roller
blind movement is signalled optically by a switched on LED. Longer pressing (>2,5 sec.) the local control push-button causes the activation
of programmed comfort settings.
Activation of the upper comfort setting:
n order to activate the upper comfort setting, open completely the roller blind. Next, press longer (>2,5 sec.) the local control push-button. The
roller blind starts closing and it will automatically stop in the adjusted upper comfort position.
Activation of the lower comfort setting:
In order to activate the lower comfort setting, close completely the roller blind. Next, press longer (>2,5 sec.) the local control push-button.
The roller blind starts opening and it will automatically stop in the adjusted low comfort position.
Caution:
Comfort setting times (upper /down) are the same in case of single and double push-button control. The programmed roller blind
movement time must be longer than times programmed for the comfort mode. After local control mode change from a single to a
double push-button, it is necessary to disconnect power supply of the device and connect it again (controller restart).
230 V AC
230 V AC