PBP - 03 BISTABLE RELAY
INSTRUCTION MANUAL
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
APPERANCE
FEATURES
DESCRIPTION
ی Bistable lighting control,
ی Time limit function,
ی Soft start and switch-off (0.8 s),
ی Load ON indicator – red LED,
ی Device triggering by means of the L
wire,
ی Applicable together with the single
pole push buttons, illuminated,
ی Two-conductor control system,
ی Easy applicable together with any
existing electrical system,
ی Supplied in series with load.
The PBP-03 bistable relay is designed
for lighting or any other unit by means of
single pole push buttons connected in
parallel. Successive pressing of any but
-
ton causes switching ON / OFF the load
connected to the output terminals alterna
-
tively. The L line is a source of a control
impulse. After the impulse has arrived
t delay time will be measured and then,
the load will be OFF. It is possible to
mount the device under a push button, in
a deep junction box of 60 mm diameter.
TECHNICAL DATA
PBP - 03
Power terminals: L (black), brown – in series with the load
Rated voltage: 230 V
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 Hz
Rated current: 8 mA
Load supply indicator: red LED
Trigger conductor: IN (red)
Load supply:
brown
ON-time adjustment range: 10 s ÷ 16 min
ON-time setting accuracy: ±3 %
ON-time setting repeatability: ±5 %
ON-time setting: continuous (rotary potentiometer)
Permissible load: 30 ÷ 300 W
Fuse technical specification: 5 x 20 mm, ultra-fast, 2 A / 250 V
Control: triac
Connection wires quantity:
3
Connection wire section: 1 mm
2
Operating temperature: -20 ÷ +45
o
C
Operating position: optional
Casing fastening: for 60 mm junction box
Casing IP: IP40
Protection class:
II
Overvoltage category:
II
Pollution level: 2
Dimensions: 50 x 50 x 15 mm
Weight: 28 g
Standard conformity: PN-EN 60669-1, PN-EN 60669-2-1,
PN-EN 61000-4-2,3,4,5,6,11
Load ON indicator
Load power lead
Power lead (L)
Fuse socket
Trigger conductor (IN)
ON-time adjustment
b
ro
w
n
r
ed
b
l
a
c
k
The timer should be
connected to a single-
phase system accordin
-
gly to current standards.
The device connections
will be described in this
manual. Only qualified electricians are
allowed to assembly, connect and ad
-
just the timer. It is necessary to read this
manual before the timer mounting. Do
not disassembly the timer casing or you
will lose any warranty rights and expo
-
se yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network. The timer
should be carried, stored and used in
an appropriate way. Do not mount the
timer in case of any device parts lack,
damage or deformation. In case of mal
-
function please notify the manufacturer.
CAUTION