5.

 

Maintenance and repairs 

 

The design  of the luminaire makes it possible to replace the light source and  power  supply 

unit (except for the version for  zone 1), which  should  be carried  out by an authorised  service. The 
lifetime of the light source and  LEDs depends on the ambient temperature of the luminaire and its 
power.  If the luminaire is  damaged, it should  be replaced  with a new or repaired  by an authorised 

service.  

 

 

Due to the explosion-proof design, any maintenance works related to the de-
vice (except for spare parts replacement specified in this manual) may only be 

conducted by the manufacturer service or by an entity authorised by the man-
ufacturer with appropriate service documentation. 
 

 
 

6.

 

Transport and storage 

 

6.1.

 

Transport 

The originally packed devices should be transported using covered means of transport.  The 

packaging should be secured against shifting and sudden shocks.   Devices should be transported at a 
temperature not lower than -20°C and not higher than +50°C. 

 

6.2.

 

Storage 

The equipment should be stored horizontally in closed areas at a temperature not lower than -

5°C and not exc40°C and away from heaters.  

 

 

7.

 

Additional information 

 

7.1.

 

CE marking 

 

 

The CE marking has been affixed under the following regulations: 

Explosion-proof equipment

 

 Directive 2014/34/EU (ATEX) 

Electromagnetic compatibility - 

Directive 2014/30/EU (EMC) 

Restriction of hazardous substances

 

 Directive 2011/65/EU (RoHS II) 

 

Information on the obtained certificates and standards applied to the equipment evaluation has been 
specified in the declaration of conformity attached to every copy of the device.  
The harmonised standards applied to demonstrate the compliance with the relevant directive are set 

out in the EU declaration of conformity supplied together with the device.   
 

7.2.

 

Special conditions for safe use 

 

for luminaires up to 100 W    -32

C ≤ Tamb ≤+55

 

for luminaires over 100 W    -32

≤ Tamb ≤+50

 

7.3.

 

Basic safety principles 

 

Before attempting any works related to the equipment, the provisions of this manual should be 
read thoroughly. 

 

Follow good engineering practices during the selection of the equipment for a given applica-
tion, during installation and during operation. 

 

The device should only be operated by personnel trained for this purpose. 

 

The safety rules of this type of equipment should be observed. 

 

Prior to the installation, check whether the marking on the rating plate satisfies requirements 
for a given application. 

 

Following the guidelines of the manual is a condition for warranty claims. 