background image

2

2

 3. Specifications

1) ZM850-HP PLUS Electrical & Physical Specifications

2) ZM1000-HP PLUS Electrical & Physical Specifications

AC Input Range

Voltage

100 ~ 240VAC

ZM850-HP PLUS

Frequency 

50 ~ 60

V

out

Output Load Rating Combined

Combined Power

AC Input Current

100VAC

11A

I

min

I

max

I

peak

240VAC

5.5A

+3.3V

0.0A

20A

180W

850W

PFC Type

Active PFC

+5V

0.5A

24A

Power Factor

MAX 99%

+12V1

0.1A

25A

27A

816W

Inrush Current Limit

(@ Cold start at 25

)

115VAC

60A

+12V2

0.0A

25A

27A

230VAC

150A

+12V3

0.0A

35A

37A

Efficiency

MAX 90% @ 230VAC, Typical load

+12V4

0.0A

28A

30A

DC Output Voltage 

Regulation

V

out

Stable Range

At Full 

Load

-12V

0.0A

0.5A

6W

+3.3VDC

±

5%

+3.14 ~ +3.47V

+5VSB

0.1A

3.5A

17.5W

+5VDC

±

5%

+4.75 ~ +5.25V

Ambient Temperature

+12V1DC

±

5%

+11.4 ~ +12.6V

Operation

0 ~ 40

+12V2DC

±

5%

+11.4 ~ +12.6V

Stored

-20 ~ 60

+12V3DC

±

5%

+11.4 ~ +12.6V

Ambient Humidity

+12V4DC

±

5%

+11.4 ~ +12.6V

Operation

10 ~ 90%RH

-12VDC

±

10%

-10.8 ~ -13.0V

Stored

5 ~ 95%RH

+5VSB

±

5%

+4.75 ~ +5.25V

Dimensions

DC Output Ripple & 

Noise

V

out

Standard Range

At Full 

Load

210(L) 

×

 150(W) 

×

 86(H)

+3.3VDC

50mV

Weight

+5VDC

50mV

4.0

(Full Package)

+12V1DC

120mV

Safety Features

+12V2DC

120mV

Over-Voltage Protection(OVP)

+12V3DC

120mV

Over-Current Protection(OCP)

+12V4DC

120mV

Under-Voltage Protection(UVP)

-12VDC

120mV

Short-Circuit Protection(SCP)

+5VSB

50mV

Over-Temperature Protection(OTP)

AC Input Range

Voltage

100 ~ 240VAC

ZM1000-HP PLUS

Frequency 

50 ~ 60

V

out

Output Load Rating Combined

Combined Power

AC Input Current

100VAC

12A

I

min

I

max

I

peak

240VAC

6A

+3.3V

0.0A

25A

180W

1000W

PFC Type

Active PFC

+5V

0.5A

30A

Power Factor

MAX 99%

+12V1

0.1A

28A

30A

984W

Inrush Current Limit

(@ Cold start at 25

)

115VAC

60A

+12V2

0.0A

25A

27A

230VAC

150A

+12V3

0.0A

35A

37A

Efficiency

MAX 90% @ 230VAC, Typical load

+12V4

0.0A

28A

30A

DC Output Voltage 

Regulation

V

out

Stable Range

At Full 

Load

-12V

0.0A

0.5A

6W

+3.3VDC

±

5%

+3.14 ~ +3.47V

+5VSB

0.1A

3.5A

17.5W

+5VDC

±

5%

+4.75 ~ +5.25V

Ambient Temperature

+12V1DC

±

5%

+11.4 ~ +12.6V

Operation

0 ~ 40

+12V2DC

±

5%

+11.4 ~ +12.6V

Stored

-20 ~ 60

+12V3DC

±

5%

+11.4 ~ +12.6V

Ambient Humidity

+12V4DC

±

5%

+11.4 ~ +12.6V

Operation

10 ~ 90%RH

-12VDC

±

10%

-10.8 ~ -13.0V

Stored

5 ~ 95%RH

+5VSB

±

5%

+4.75 ~ +5.25V

Dimensions

DC Output Ripple & 

Noise

V

out

Standard Range

At Full 

Load

210(L) 

×

 150(W) 

×

 86(H)

+3.3VDC

50mV

Weight

+5VDC

50mV

4.0

(Full Package)

+12V1DC

120mV

Safety Features

+12V2DC

120mV

Over-Voltage Protection(OVP)

+12V3DC

120mV

Over-Current Protection(OCP)

+12V4DC

120mV

Under-Voltage Protection(UVP)

-12VDC

120mV

Short-Circuit Protection(SCP)

+5VSB

50mV

Over-Temperature Protection(OTP)

Reviews: