HE2K-MINI-RPS User Guide
DOC-USR-0232-02
______________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
49
8.6.1
Com2TCP Setup
(1)
If you have not already done so, install the Com2TCP application onto your PC. (For Windows 8 or
above, verify you are using v1.4.6.) Com2TCP is an application supporting remote access and is
available online.
(2)
Launch the Com2TCP application.
(3)
Set the
Remote IP
field to the IP address of your HE2K-MINI-RPS. This can be found using ZFinder or
as the URL of the web browser with the user interface open.
(4)
Set the
TCP Port
to
1000
. This value must match the Camera 1 (VISCA) TCP Port value listed in the term tab of the
FV2K-DCK-1X user interface.
(5)
Assign a
COM Port
that is not currently in use on your system using the dropdown menu.
(6)
Click the
Connect
button. The application will minimize. Do not close this application while your
camera control is in use.
The COM port selected will now redirect data to the HE2K-MINI-RPS.
If the camera is rebooted or power cycled, you will need to reconnect COM2TCP on your PC. COM2TCP
does
not
automatically detect the dropped connection.
Figure 46 Com2TCP Configuration
Set to “1000”
Set to the IP
Address of
Your Z3 Unit