48
Wildcat (BL2000)
Sets the voltage of a D/A converter output channel by serially clocking in 16 bits to a D/A converter
using the following format:
D15–D14
Doesn’t matter.
D13–D12
Mode of operation
00—Normal Operation
01—Software Powerdown, 1 k
Ω
to GND
10—Software Powerdown, 100 k
Ω
to GND
11—Software Powerdown, three-state
D11–D0
Data bits, MSB–LSB (0–4095)
PARAMETERS
channel
is the D/A converter output channel to write (0 or 1).
modecount
is a value corresponding to the voltage on the D/A converter output and/or setting the
mode of operation
:
RETURN VALUE
None
SEE ALSO
anaOutVolts, anaOutCalib, brdInit
void anaOut(unsigned int channel, unsigned int
modecount);
Operation
Mode
Description
modecount
Value
0
Normal Mode
0–4095
1
Software Powerdown, 1 k
Ω
to GND
0x1000
2
Software Powerdown, 100 k
Ω
to GND
0x2000
3
Software Powerdown, three-state
0x3000