Cool set point (report in precision of 0.5
o
C or 1
o
F)
g)
Current room temperature (report in precision of 0.5
o
C or 1
o
F)
(It will trigger room temperature report if there is 2
o
F / 1
o
C [default] differ from last report.
You can change this setting by set the configuration parameter)
Notes:
Total 5 devices (nodes) can be assigned in total 3 association groups. Below table lists out the devices
(nodes) allocations in the 3 association groups.
No. of Node ID in
Association Group_1
No. of Node ID in
Association Group_2
No. of Node ID in
Association Group_3
1 (AUTO report)
0,1 or 2 nodes
0,1 or 2 nodes
Important:
Please do not associate heater and compressor devices in same association group because heater and
compressor device can’t turn on in simultaneously!
Example: Association groups setting
F-BW8170 (ZTS-500)
F-BW8041 (ZFM-80)
(Node ID-B)
F-BW8041 (ZFM-80)
(Node ID-C)
Z-Wave Gateway
(Node ID-A)
Association group_2
for Heater
Association group_3
for Compressor
Association group_1
for Auto report to gateway
F-BW8041 (ZFM-80)
(Node ID-D)
F-BW8041 (ZFM-80)
(Node ID-E)