Z-Wave ZME WallC-S2 Quick Start Download Page 4

Command to control Group B (Parameter 12, Size 1) 

This parameter defines the command to be sent to devices of control group B 

when the related button is pressed. 

Value  Description

Disabled

Switch On/Off and Dim (send Basic Set and Switch Multilevel)

Switch On/Off only (send Basic Set)

Switch All

Send Scenes

Send Preconfigured Scenes

Control Door Lock

Central Scene to Gateway (Default)

Command to control Group C (Parameter 13, Size 1) 

This parameter defines the command to be sent to devices of control group C 

when the related button is pressed. 

Value  Description

Disabled

Switch On/Off and Dim (send Basic Set and Switch Multilevel)

Switch On/Off only (send Basic Set)

Switch All

Send Scenes

Send Preconfigured Scenes

Control Door Lock

Central Scene to Gateway (Default)

Command to control Group D (Parameter 14, Size 1) 

This parameter defines the command to be sent to devices of control group D 

when the related button is pressed. 

Value  Description

Disabled

Switch On/Off and Dim (send Basic Set and Switch Multilevel)

Switch On/Off only (send Basic Set)

Switch All

Send Scenes

Send Preconfigured Scenes

Control Door Lock

Central Scene to Gateway (Default)

Send the following switch all commands (Number 21, Size 1)

 

Value  Description

Switch off only (Default) 

Switch on only 

255

Switch all on and off

Invert buttons (Number 22, Size 1)

 

Value  Description

No (Default)

Yes

Blocks wake up even when Wake Up Interval is set 

(Number 25, Size 1)

 

If the Wall Controller wakes up and there is no controller nearby, several 

unsuccessful communication attempts will drain battery. 

Value  Description

Wake up is blocked (Default)

Wake up is possible if configured  accordingly 

Send unsolicited battery report on Wake Up (Number 30, Size 1)

 

If the Wall Controller wakes up and there is no controller nearby, several 

unsuccessful communication attempts will drain battery.

Value  Description

No

To same node as Wake Up Notification (Default)

Broadcast to neighbors

Batteries 

The unit is operated by batteries. Use only batteries of correct type. Never mix 

old and new batteries in the same device. Used batteries contain hazardous 

substances and should not be disposed of with household waste! 

Technical Data 

IP Rating 

IP 20 

Battery Type 

1 * CR2032 

Frequency 

868.42 MHz 

Wireless Range 

Up to 100 m outside, on average up to 20 m inside 

buildings 

Explorer Frame 

Support 

No 

Device Type 

Portable Controller 

Routing 

No 

FLiRS 

No

 

Firmware Version 

1.3 

Battery Life 

> 2 years 

Z-Wave.Me  guarantees that every device is free from physical defects in material and 

workmanship under normal use for one year from the date of purchase. If the product proves 

defective during this one-year warranty period, Z-Wave.Me will replace it free of charge. Z-

Wave.Me does not issue any refunds. This warranty is extended to the original end user 

purchase only and is not transferable. This warranty does not apply to: (1) damage to units 

caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have 

been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in 

accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, 

initial installation costs, removal cost, or reinstallation cost. For information on additional 

devices, please visit us online. 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference in a residential installation. This equipment generates, 

uses and can radiate radio frequency energy and if not installed and used in accordance with 

the instructions, may cause harmful interference to radio communications. However, there is 

no guarantee that interference will not occur in a particular installation. If this equipment does 

cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or 

more of the following measures:  

(1)  Reorient or relocate the receiving antenna. (2)  Increase the separation between the 

equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV 

technician for help.  Any changes or modification not expressly approved by the party 

responsible for compliance could void the user's authority to operate the device.  

Where shielded interface cables have been provided with the product or specified additional 

components or accessories elsewhere defined to be used with the installation of the product, 

they must be used in order to ensure compliance with FCC regulations. 

CE for Class B ITE (Following European standard EN55022/1998; EN61000-  3-2/1995; 

EN61000-3-3/1995, EN55024/1998, EN60950-1/2001) 