Command to control Group B (Parameter 12, Size 1)
This parameter defines the command to be sent to devices of control group B
when the related button is pressed.
Value Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
7
Control Door Lock
8
Central Scene to Gateway (Default)
Command to control Group C (Parameter 13, Size 1)
This parameter defines the command to be sent to devices of control group C
when the related button is pressed.
Value Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
7
Control Door Lock
8
Central Scene to Gateway (Default)
Command to control Group D (Parameter 14, Size 1)
This parameter defines the command to be sent to devices of control group D
when the related button is pressed.
Value Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
7
Control Door Lock
8
Central Scene to Gateway (Default)
Send the following switch all commands (Number 21, Size 1)
Value Description
1
Switch off only (Default)
2
Switch on only
255
Switch all on and off
Invert buttons (Number 22, Size 1)
Value Description
0
No (Default)
1
Yes
Blocks wake up even when Wake Up Interval is set
(Number 25, Size 1)
If the Wall Controller wakes up and there is no controller nearby, several
unsuccessful communication attempts will drain battery.
Value Description
0
Wake up is blocked (Default)
1
Wake up is possible if configured accordingly
Send unsolicited battery report on Wake Up (Number 30, Size 1)
If the Wall Controller wakes up and there is no controller nearby, several
unsuccessful communication attempts will drain battery.
Value Description
0
No
1
To same node as Wake Up Notification (Default)
2
Broadcast to neighbors
Batteries
The unit is operated by batteries. Use only batteries of correct type. Never mix
old and new batteries in the same device. Used batteries contain hazardous
substances and should not be disposed of with household waste!
Technical Data
IP Rating
IP 20
Battery Type
1 * CR2032
Frequency
868.42 MHz
Wireless Range
Up to 100 m outside, on average up to 20 m inside
buildings
Explorer Frame
Support
No
Device Type
Portable Controller
Routing
No
FLiRS
No
Firmware Version
1.3
Battery Life
> 2 years
Z-Wave.Me guarantees that every device is free from physical defects in material and
workmanship under normal use for one year from the date of purchase. If the product proves
defective during this one-year warranty period, Z-Wave.Me will replace it free of charge. Z-
Wave.Me does not issue any refunds. This warranty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to: (1) damage to units
caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have
been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in
accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage,
initial installation costs, removal cost, or reinstallation cost. For information on additional
devices, please visit us online.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
(1) Reorient or relocate the receiving antenna. (2) Increase the separation between the
equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV
technician for help. Any changes or modification not expressly approved by the party
responsible for compliance could void the user's authority to operate the device.
Where shielded interface cables have been provided with the product or specified additional
components or accessories elsewhere defined to be used with the installation of the product,
they must be used in order to ensure compliance with FCC regulations.
CE for Class B ITE (Following European standard EN55022/1998; EN61000- 3-2/1995;
EN61000-3-3/1995, EN55024/1998, EN60950-1/2001)
4
Summary of Contents for ZME WallC-S2
Page 5: ......